MMP7 CLIA Kit

MMP7 Reactivity: Rat Chemiluminescent Sandwich ELISA 156.25 pg/mL - 10000 pg/mL Plasma, Serum
Catalog No. ABIN5656780
  • Target See all MMP7 CLIA Kits
    MMP7 (Matrix Metallopeptidase 7 (Matrilysin, Uterine) (MMP7))
    Reactivity
    • 7
    • 5
    • 2
    • 2
    • 2
    • 1
    • 1
    • 1
    • 1
    • 1
    • 1
    • 1
    • 1
    Rat
    Detection Method
    Chemiluminescent
    Method Type
    Sandwich ELISA
    Detection Range
    156.25 pg/mL - 10000 pg/mL
    Minimum Detection Limit
    156.25 pg/mL
    Application
    ELISA
    Sample Type
    Plasma, Serum
    Analytical Method
    Quantitative
    Specificity
    This assay has high sensitivity and excellent specificity for detection of Matrix Metalloproteinase 7 (MMP7). No significant cross-reactivity or interference between Matrix Metalloproteinase 7 (MMP7) and analogues was observed.
    Sensitivity
    6.29 pg/mL
    Featured
    Discover our best selling MMP7 ELISA Kit
    Top Product
    Discover our top product MMP7 ELISA Kit
  • Comment

    The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5 % within the expiration date under appropriate storage condition. To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

    Assay Time
    2 - 3 h
    Plate
    Pre-coated
    Protocol
    The microplate provided in this kit has been pre-coated with an antibody specific to Matrix Metalloproteinase 7 (MMP7). Standards or samples are then added to the appropriate microplate wells with a biotin-conjugated antibody specific to Matrix Metalloproteinase 7 (MMP7). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. Then the mixture of substrate A and B is added to generate glow light emission kinetics. Upon plate development, the intensity of the emitted light is proportional to the Matrix Metalloproteinase 7 (MMP7) level in the sample or standard.,
    Assay Precision
    Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Matrix Metalloproteinase 7 (MMP7) were tested 20 times on one plate, respectively
    Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Matrix Metalloproteinase 7 (MMP7) were tested on 3 different plates, 8 replicates in each plate. CV(%) = SD/meanX100
    Intra-Assay: CV<10%
    Inter-Assay: CV<12%
    Restrictions
    For Research Use only
  • Handling Advice
    Do not allow to contact skin or eyes. Calibrators, controls and specimen samples should be assayed in duplicate. Once the procedure has been started, all steps should be completed without interruption.
    Storage
    4 °C,-20 °C
    Storage Comment
    -20°C. Bring all reagents to room temperature before beginning test. The kit may be stored at 4°C for immediate use within two days upon arrival. Reseal any unused strips with desiccant pack. Minimize freeze/thaw cycles.
    Expiry Date
    4-8 months
  • Target See all MMP7 CLIA Kits
    MMP7 (Matrix Metallopeptidase 7 (Matrilysin, Uterine) (MMP7))
    Alternative Name
    Matrix Metalloproteinase 7 (MMP7 Products)
    Synonyms
    MAT CLIA Kit, MPMM CLIA Kit, MMP-7 CLIA Kit, MPSL1 CLIA Kit, PUMP-1 CLIA Kit, matrilysin CLIA Kit, LOC727698 CLIA Kit, MMP7 CLIA Kit, Matrilysin CLIA Kit, matrix metallopeptidase 7 CLIA Kit, MMP7 CLIA Kit, Mmp7 CLIA Kit
    Background

    Gene Name: Matrix Metalloproteinase 7

    Gene Aliases: MPSL1, MAT, PUMP-1, Matrilysin Uterine, Matrilysin, Matrin, Pump-1 Protease, Uterine Metalloproteinase

    Gene ID
    25335
    UniProt
    P50280
    Pathways
    Production of Molecular Mediator of Immune Response
You are here:
Support