MACC1 ELISA Kit
Quick Overview for MACC1 ELISA Kit (ABIN5656849)
Target
See all MACC1 ELISA KitsReactivity
Detection Method
Method Type
Detection Range
Application
Sample Type
-
-
Minimum Detection Limit
- 0.312 ng/mL
-
Purpose
- Human Metastasis Associated In Colon Cancer 1 (MACC1) ELISA Kit for detecting MACC1 in serum, plasma, tissue homogenates
-
Analytical Method
- Quantitative
-
Specificity
- This assay has high sensitivity and excellent specificity for detection of Metastasis Associated In Colon Cancer 1 (MACC1). No significant cross-reactivity or interference between Metastasis Associated In Colon Cancer 1 (MACC1) and analogues was observed.
-
Sensitivity
- 0.122 ng/mL
-
Components
-
- Pre-coated, ready to use 96-well strip plate
- Standar
- Detection Reagent A
- Detection Reagent B
- TMB Substrate
- Stop Solution
- Assay Diluent A
- Assay Diluent B
- Wash Buffer (30x concentrate)
- Standard Diluent
- Plate Sealer
- Instruction Manual
-
Material not included
-
- Microplate Reader with 450 nm filter
- Single or multi-channel pipettes with high precision and disposable tips
- Microcentrifuge tubes
- Deionized or distilled watter
- Absorbent paper for blotting the microplate
- Container for wash solution
- 0.01 M (or 1x) Phosphate Buffered Saline (PBS), ph 7.0-7.2
-
-
-
-
Application Notes
- Optimal working dilution should be determined by the investigator.
-
Comment
-
This product is tested and assembled before shipping to ensure that it meets its quality specifications. All kits are tested to confirm that they fall within their defined Inter- and Intra- assay coefficient of variation.
-
Sample Volume
- 100 μL
-
Assay Time
- 3 h
-
Plate
- Pre-coated
-
Protocol
- The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Metastasis Associated In Colon Cancer 1 (MACC1). Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated antibody specific to Metastasis Associated In Colon Cancer 1 (MACC1). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Metastasis Associated In Colon Cancer 1 (MACC1), biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Metastasis Associated In Colon Cancer 1 (MACC1) in the samples is then determined by comparing the O.D. of the samples to the standard curve.
-
Assay Precision
-
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Metastasis Associated In Colon Cancer 1 (MACC1) were tested 20 times on one plate, respectively
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Metastasis Associated In Colon Cancer 1 (MACC1) were tested on 3 different plates, 8 replicates in each plate. CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12% -
Restrictions
- For Research Use only
-
-
-
Handling Advice
- The Stop Solution is acidic. Do not allow to contact skin or eyes. Calibrators, controls and specimen samples should be assayed in duplicate. Once the procedure has been started, all steps should be completed without interruption.
-
Storage
- 4 °C,-20 °C
-
Storage Comment
- -20°C. Bring all reagents to room temperature before beginning test. The kit may be stored at 4°C for immediate use within two days upon arrival. Reseal any unused strips with desiccant pack. Minimize freeze/thaw cycles.
-
Expiry Date
- 12 months
-
-
- MACC1 (Metastasis Associated in Colon Cancer 1 (MACC1))
-
Alternative Name
- Metastasis Associated In Colon Cancer 1
-
Background
- Gene Aliases: 7A5, SH3BP4L, SH3 domain-containing protein 7a5
-
Gene ID
- 346389
-
UniProt
- Q6ZN28
Target See all MACC1 ELISA Kits
-