OTC ELISA Kit
Quick Overview for OTC ELISA Kit (ABIN5657520)
Target
See all OTC ELISA KitsReactivity
Detection Method
Method Type
Detection Range
Application
Sample Type
-
-
Minimum Detection Limit
- 0.312 ng/mL
-
Analytical Method
- Quantitative
-
Specificity
- This assay has high sensitivity and excellent specificity for detection of Ornithine Carbamoyl Transferase (OCT). No significant cross-reactivity or interference between Ornithine Carbamoyl Transferase (OCT) and analogues was observed.
-
Sensitivity
- 0.128 ng/mL
-
-
-
-
Comment
-
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5 % within the expiration date under appropriate storage condition. To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
-
Assay Time
- 3 h
-
Plate
- Pre-coated
-
Protocol
- The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Ornithine Carbamoyl Transferase (OCT). Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated antibody specific to Ornithine Carbamoyl Transferase (OCT). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Ornithine Carbamoyl Transferase (OCT), biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Ornithine Carbamoyl Transferase (OCT) in the samples is then determined by comparing the O.D. of the samples to the standard curve.
-
Assay Precision
-
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Ornithine Carbamoyl Transferase (OCT) were tested 20 times on one plate, respectively
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Ornithine Carbamoyl Transferase (OCT) were tested on 3 different plates, 8 replicates in each plate. CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12% -
Restrictions
- For Research Use only
-
-
-
Handling Advice
- The Stop Solution is acidic. Do not allow to contact skin or eyes. Calibrators, controls and specimen samples should be assayed in duplicate. Once the procedure has been started, all steps should be completed without interruption.
-
Storage
- 4 °C,-20 °C
-
Storage Comment
- -20°C. Bring all reagents to room temperature before beginning test. The kit may be stored at 4°C for immediate use within two days upon arrival. Reseal any unused strips with desiccant pack. Minimize freeze/thaw cycles.
-
Expiry Date
- 4-8 months
-
-
- OTC (Ornithine Carbamoyltransferase (OTC))
-
Alternative Name
- Ornithine Carbamoyl Transferase
-
Background
-
Gene Name: Ornithine Carbamoyl Transferase
Gene Aliases: OCTD, OTCase, Ornithine Transcarbamylase, Ornithine Carbamoyltransferase
-
Gene ID
- 5009
-
UniProt
- P00480
Target See all OTC ELISA Kits
-