Phone:
+1 877 302 8632
Fax:
+1 888 205 9894 (Toll-free)
E-Mail:
orders@antibodies-online.com

CCL21 ELISA Kit

Human CCL21 ELISA Kit, Colorimetric assay for quantification of Human CCL21.
Catalog No. ABIN5658617
$1,031.31
Plus shipping costs $50.00
96 tests
Shipping to: United States
Delivery in 8 to 13 Business Days

Quick Overview for CCL21 ELISA Kit (ABIN5658617)

Target

See all CCL21 ELISA Kits
CCL21 (Chemokine (C-C Motif) Ligand 21 (CCL21))

Reactivity

  • 19
  • 18
  • 4
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
Human

Detection Method

Colorimetric

Method Type

Sandwich ELISA

Detection Range

31.2 pg/mL - 2000 pg/mL

Application

ELISA

Sample Type

Cell Culture Supernatant, Cell Lysate, Plasma, Serum, Tissue Homogenate
  • Minimum Detection Limit

    31.2 pg/mL

    Purpose

    Human Secondary Lymphoid Tissue Chemokine (SLC) ELISA Kit for detecting SLC in serum, plasma, tissue homogenates, cell lysates, cell culture supernates

    Analytical Method

    Quantitative

    Specificity

    This assay has high sensitivity and excellent specificity for detection of Secondary Lymphoid Tissue Chemokine (SLC). No significant cross-reactivity or interference between Secondary Lymphoid Tissue Chemokine (SLC) and analogues was observed.

    Sensitivity

    12.7 pg/mL

    Components

    • Pre-coated, ready to use 96-well strip plate
    • Standar
    • Detection Reagent A
    • Detection Reagent B
    • TMB Substrate
    • Stop Solution
    • Assay Diluent A
    • Assay Diluent B
    • Wash Buffer (30x concentrate)
    • Standard Diluent
    • Plate Sealer
    • Instruction Manual

    Material not included

    • Microplate Reader with 450 nm filter
    • Single or multi-channel pipettes with high precision and disposable tips
    • Microcentrifuge tubes
    • Deionized or distilled watter
    • Absorbent paper for blotting the microplate
    • Container for wash solution
    • 0.01 M (or 1x) Phosphate Buffered Saline (PBS), ph 7.0-7.2
  • Application Notes

    Optimal working dilution should be determined by the investigator.

    Comment

    This product is tested and assembled before shipping to ensure that it meets its quality specifications. All kits are tested to confirm that they fall within their defined Inter- and Intra- assay coefficient of variation.

    Sample Volume

    100 μL

    Assay Time

    3 h

    Plate

    Pre-coated

    Protocol

    The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Secondary Lymphoid Tissue Chemokine (SLC). Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated antibody specific to Secondary Lymphoid Tissue Chemokine (SLC). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Secondary Lymphoid Tissue Chemokine (SLC), biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Secondary Lymphoid Tissue Chemokine (SLC) in the samples is then determined by comparing the O.D. of the samples to the standard curve.

    Assay Precision

    Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Secondary Lymphoid Tissue Chemokine (SLC) were tested 20 times on one plate, respectively
    Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Secondary Lymphoid Tissue Chemokine (SLC) were tested on 3 different plates, 8 replicates in each plate. CV(%) = SD/meanX100
    Intra-Assay: CV<10%
    Inter-Assay: CV<12%

    Restrictions

    For Research Use only
  • Handling Advice

    The Stop Solution is acidic. Do not allow to contact skin or eyes. Calibrators, controls and specimen samples should be assayed in duplicate. Once the procedure has been started, all steps should be completed without interruption.

    Storage

    4 °C,-20 °C

    Storage Comment

    -20°C. Bring all reagents to room temperature before beginning test. The kit may be stored at 4°C for immediate use within two days upon arrival. Reseal any unused strips with desiccant pack. Minimize freeze/thaw cycles.

    Expiry Date

    12 months
  • Target See all CCL21 ELISA Kits

    CCL21 (Chemokine (C-C Motif) Ligand 21 (CCL21))

    Alternative Name

    Secondary Lymphoid Tissue Chemokine

    Background

    Gene Aliases: CCL21, 6Ckine, CKb9, ECL, SCYA21, TCA4, ECL, Chemokine (C-C-Motif) Ligand 21, Beta Chemokine Exodus-2, Efficient Chemoattractant For Lymphocytes

    Gene ID

    6366

    UniProt

    Q6ICR7

    Pathways

    Regulation of Actin Filament Polymerization