SFRP1 ELISA Kit (Secreted Frizzled-Related Protein 1)

Details for Product SFRP1 ELISA Kit No. ABIN5658625, Supplier: Log in to see
Antigen
  • FRP
  • FRP-1
  • FRP1
  • FrzA
  • SARP2
  • 2210415K03Rik
  • AW011917
  • AW107218
  • AW742929
  • sFRP-1
  • CSFRP1
  • SFRP1
  • XfrzA
  • frp
  • frp-1
  • frp1
  • frzA
  • sarp2
  • sfrp1
  • LOC100231868
  • secreted frizzled related protein 1
  • secreted frizzled-related protein 1
  • Secreted frizzled-related protein 1
  • secreted frizzled-related protein 1b
  • SFRP1
  • Sfrp1
  • sfrp1
  • sfrp1b
Reactivity
Rat (Rattus)
Alternatives
Kits with alternative reactivity to:
15
10
8
2
2
2
1
1
1
1
1
Method Type
Sandwich ELISA
Detection Range
0.156 ng/mL - 10 ng/mL
Minimum Detection Limit
0.156 ng/mL
Application
ELISA
Options
Supplier
Log in to see
Supplier Product No.
Log in to see
Sample Type Plasma, Serum, Tissue Homogenate
Analytical Method Quantitative
Detection Method Colorimetric
Specificity This assay has high sensitivity and excellent specificity for detection of Secreted Frizzled Related Protein 1 (SFRP1). No significant cross-reactivity or interference between Secreted Frizzled Related Protein 1 (SFRP1) and analogues was observed.
Sensitivity 0.055 ng/mL
Plasmids, Primers & others Plasmids, Primers & others SFRP1 products on genomics-online (e.g. as negative or positive controls)
Antigen
Alternative Name Secreted Frizzled Related Protein 1 (SFRP1 ELISA Kit Abstract)
Background

Gene Name: Secreted Frizzled Related Protein 1

Gene Aliases: FRP1, FRP, FRP-1, FrzA, SARP2, Secreted apoptosis-related protein 2

UniProt Q9R168
Pathways WNT Signaling, Intracellular Steroid Hormone Receptor Signaling Pathway, Negative Regulation of Hormone Secretion, Regulation of Intracellular Steroid Hormone Receptor Signaling, Stem Cell Maintenance, Tube Formation, Positive Regulation of fat Cell Differentiation
Comment

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5 % within the expiration date under appropriate storage condition. To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Assay Time 3 h
Plate Pre-coated
Protocol The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Secreted Frizzled Related Protein 1 (SFRP1). Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated antibody specific to Secreted Frizzled Related Protein 1 (SFRP1). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Secreted Frizzled Related Protein 1 (SFRP1), biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Secreted Frizzled Related Protein 1 (SFRP1) in the samples is then determined by comparing the O.D. of the samples to the standard curve.
Assay Precision Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Secreted Frizzled Related Protein 1 (SFRP1) were tested 20 times on one plate, respectively
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Secreted Frizzled Related Protein 1 (SFRP1) were tested on 3 different plates, 8 replicates in each plate. CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
Restrictions For Research Use only
Handling Advice The Stop Solution is acidic. Do not allow to contact skin or eyes. Calibrators, controls and specimen samples should be assayed in duplicate. Once the procedure has been started, all steps should be completed without interruption.
Storage 4 °C,-20 °C
Storage Comment -20°C. Bring all reagents to room temperature before beginning test. The kit may be stored at 4°C for immediate use within two days upon arrival. Reseal any unused strips with desiccant pack. Minimize freeze/thaw cycles.
Expiry Date 4-8 months
Did you look for something else?