Phone:
+1 877 302 8632
Fax:
+1 888 205 9894 (Toll-free)
E-Mail:
orders@antibodies-online.com

H2AFX ELISA Kit

This Colorimetric ELISA kit is designed for the quantitative measurement of Human H2AFX.
Catalog No. ABIN6228783

Quick Overview for H2AFX ELISA Kit (ABIN6228783)

Target

See all H2AFX ELISA Kits
H2AFX (H2A Histone Family, Member X (H2AFX))

Reactivity

  • 6
  • 4
  • 2
Human

Detection Method

Colorimetric

Method Type

Sandwich ELISA

Detection Range

78 pg/mL - 5000 pg/mL

Application

ELISA

Sample Type

Cell Lysate, Tissue Homogenate
  • Minimum Detection Limit

    78 pg/mL

    Purpose

    Human Histone H2AX (H2AFX) ELISA Kit

    Analytical Method

    Quantitative

    Sensitivity

    47 pg/mL

    Components

    The kit components listed are for reference only. The product manual may differ slightly. The product should be used as stated on the product manual included and delivered together with the product.
    • Pre-coated 96-Well Microplate
    • Standard
    • Standard Diluent Buffer
    • Wash Buffer
    • Detection Reagent A
    • Detection Reagent B
    • Diluent A
    • Diluent B
    • TMB Substrate
    • Stop Solution
    • Plate Sealer

    Material not included

    • 37 °C incubator
    • Multi and single channel pipettes and sterile pipette tips
    • Squirt bottle or automated microplate washer
    • 1.5 mL tubes
    • Distilled water
    • Absorbent filter papers
    • 100 mL and 1 liter graduated cylinders
    • Microplate reader (wavelength: 450 nm)
    • ELISA Shaker
  • Application Notes

    Optimal dilutions/concentrations should be determined by the end user.

    Comment

    The stability of the kit is determined by the rate of activity loss. The loss rate is less than 5 % within the expiration date under appropriate storage conditions. To minimize performance fluctuations, operation procedures and lab conditions should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same user throughout.

    Plate

    Pre-coated

    Assay Precision

    Intra-assay Precision (Precision within an assay): 3 samples with low, medium and high levels of Histone H2AX (H2AFX) were tested 20 times on one plate, respectively.

    Inter-assay Precision (Precision between assays): 3 samples with low, medium and high levels of Histone H2AX (H2AFX) were tested on 3 different plates, 8 replicates in each plate.

    CV (%) = (Standard Deviation / mean) x 100

    Intra-Assay: CV<10%

    Inter-Assay: CV<10%

    Restrictions

    For Research Use only
  • Storage

    4 °C

    Storage Comment

    Shipped at 4 °C. Upon receipt, store the kit according to the storage instruction in the kit's manual.

    Expiry Date

    6 months
  • Target See all H2AFX ELISA Kits

    H2AFX (H2A Histone Family, Member X (H2AFX))

    Alternative Name

    Histone H2AX

    Background

    H2AX_HUMAN

    Gene ID

    3014

    HGNC

    4739

    OMIM

    601772

    UniProt

    P16104

    Pathways

    Telomere Maintenance, DNA Damage Repair, Positive Regulation of Response to DNA Damage Stimulus
You are here: