CXCL3 ELISA Kit
Quick Overview for CXCL3 ELISA Kit (ABIN6719965)
Target
See all CXCL3 ELISA KitsReactivity
Detection Method
Method Type
Detection Range
Application
Sample Type
-
-
Minimum Detection Limit
- 15.6 pg/mL
-
Supplier Product No.
- koa0832
-
Supplier
- Rockland
-
Purpose
- Rat CXCL3 Sandwich ELISA Kit for Quantitative Detection
-
Brand
- AccuSignal™
-
Analytical Method
- Quantitative
-
Specificity
-
Expression system for standard: E.coli
Immunogen sequence: R33-S101 -
Cross-Reactivity (Details)
- There is no detectable cross-reactivity with other relevant proteins.
-
Sensitivity
- < 10 pg/mL
-
Components
-
- Antibody-coated 96-well plate
- Target Protein Standard
- Detection antibody
- Detection reagent
- Diluent buffers
- Wash buffers
- Substrate Solution
- Stop solutions
- Adhesive covers
-
Material not included
- Microplate Reader capable of reading absorbance at 450nm. Incubator. Automated plate washer (optional). Pipettes and pipette tips capable of precisely dispensing 0.5 μL through 1 mL volumes of aqueous solutions. Multichannel pipettes are recommended for large amount of samples. Deionized or distilled water. 500 mL graduated cylinders. Test tubes for dilution.
-
-
-
-
Comment
-
Capture antibody and Detection antibody: monoclonal antibody from mouse, polyclonal antibody from goat
-
Sample Volume
- 100 μL
-
Plate
- Pre-coated
-
Protocol
- Useful in Sandwich ELISA for Quantitative Detection of Antigen. Aliquot 0.1 mL per well of the 1000pg/mL, 500pg/mL, 250pg/mL, 125pg/mL, 62.5pg/mL, 31.2pg/mL, 15.6pg/mL rat CXCL3 standard solutions into the precoated 96-well plate. Add 0.1 mL of the sample diluent buffer into the control well (Zero well). Add 0.1 mL of each properly diluted sample of rat cell culture supernates, serum or plasma(heparin, EDTA) to each empty well. It is recommended that each rat CXCL3 standard solution and each sample be measured in duplicate.
-
Assay Precision
-
Intra-Assay Precision (CV%): 7.1%, 7.8%, 4.9%
Inter-Assay Precision (CV%): 7.2%, 9.7%, 5.2% -
Restrictions
- For Research Use only
-
-
-
Storage
- 4 °C,-20 °C
-
Storage Comment
- Store vials at 4°C prior to opening. Centrifuge product if not completely clear after standing at room temperature. This product is stable for 6 months at 4°C as an undiluted liquid. Dilute only prior to immediate use. For extended storage freeze at -20°C or below for 12 months. Avoid cycles of freezing and thawing.
-
Expiry Date
- 12 months
-
-
- CXCL3 (Chemokine (C-X-C Motif) Ligand 3 (CXCL3))
-
Alternative Name
- CXCL3
-
Background
-
Background: Chemokine (C-X-C motif) ligand 3 (CXCL3) is a small cytokine belonging to the CXC chemokine family. It is mapped to 14p2 in rat. CXCL3 controls migration and adhesion of monocytes and mediates its effects on its target cell by interacting with a cell surface chemokine receptor. It has been shown that CXCL3 regulates cell autonomously the migration of the precursors of cerebellar granule neurons toward the internal layers of cerebellum, during the morphogenesis of cerebellum. CXCL3 also play fundamental roles in the development, homeostasis and it has effects on cells of the central nervous system as well as on endothelial cells involved in angiogenesis or angiostasis.
Gene Full Name: C-X-C motif chemokine ligand 3
-
Gene ID
- 171551
-
NCBI Accession
- NP_612531
-
UniProt
- Q10746
-
Pathways
- Cellular Response to Molecule of Bacterial Origin, Autophagy
Target See all CXCL3 ELISA Kits
-