CCL3 ELISA Kit
Quick Overview for CCL3 ELISA Kit (ABIN6720005)
Target
See all CCL3 ELISA KitsReactivity
Detection Method
Method Type
Detection Range
Application
Sample Type
-
-
Minimum Detection Limit
- 7.8 pg/mL
-
Supplier Product No.
- koa0712
-
Supplier
- Rockland
-
Purpose
- Rat MIP-1 alpha - CCL3 Sandwich ELISA Kit for Quantitative Detection
-
Brand
- AccuSignal™
-
Analytical Method
- Quantitative
-
Specificity
-
Expression system for standard: E.coli
Immunogen sequence: A24-A92 -
Cross-Reactivity (Details)
- There is no detectable cross-reactivity with other relevant proteins.
-
Sensitivity
- < 1 pg/mL
-
Components
-
- Antibody-coated 96-well plate
- Target Protein Standard
- Detection antibody
- Detection reagent
- Diluent buffers
- Wash buffers
- Substrate Solution
- Stop solutions
- Adhesive covers
-
Material not included
- Microplate Reader capable of reading absorbance at 450nm. Incubator. Automated plate washer (optional). Pipettes and pipette tips capable of precisely dispensing 0.5 μL through 1 mL volumes of aqueous solutions. Multichannel pipettes are recommended for large amount of samples. Deionized or distilled water. 500 mL graduated cylinders. Test tubes for dilution.
-
-
-
-
Comment
-
Capture antibody and Detection antibody: monoclonal antibody from mouse, polyclonal antibody from goat
-
Sample Volume
- 100 μL
-
Plate
- Pre-coated
-
Protocol
- Useful in Sandwich ELISA for Quantitative Detection of Antigen. Aliquot 0.1 mL per well of the 500pg/mL, 250pg/mL, 125pg/mL, 62.5pg/mL, 31.3pg/mL, 15.6pg/mL, 7.8pg/mL rat MIP-1α standard solutions into the precoated 96-well plate. Add 0.1 mL of the sample diluent buffer into the control well (Zero well). Add 0.1 mL of each properly diluted sample of rat cell culture supernates, serum or plasma(heparin, EDTA, citrate) to each empty well. It is recommended that each rat MIP-1α standard solution and each sample be measured in duplicate.
-
Assay Precision
-
Intra-Assay Precision (CV%): 6%, 6.7%, 5.9%
Inter-Assay Precision (CV%): 6.2%, 8%, 6% -
Restrictions
- For Research Use only
-
-
-
Storage
- 4 °C,-20 °C
-
Storage Comment
- Store vials at 4°C prior to opening. Centrifuge product if not completely clear after standing at room temperature. This product is stable for 6 months at 4°C as an undiluted liquid. Dilute only prior to immediate use. For extended storage freeze at -20°C or below for 12 months. Avoid cycles of freezing and thawing.
-
Expiry Date
- 12 months
-
-
- CCL3 (Chemokine (C-C Motif) Ligand 3 (CCL3))
-
Alternative Name
- MIP-1 alpha/CCL3
-
Background
-
Background: Macrophage inflammatory protein-1 alpha (MIP-1 alpha), also called CCL3, LD78. The cDNA for MIP-1 alpha predicts a mature peptide of 69 amino acids with a molecular mass of 7,889 daltons. LD78 is a member of a newly identified superfamily of small inducible proteins involved in inflammatory responses, wound healing and tumorigenesis. MIP-1 alpha is a chemokine that has pro-inflammatory and stem cell inhibitory activities in vitro. It constitutes an important second signal for mast cell degranulation in the conjunctiva in vivo and consequently for acute-phase disease.
Gene Full Name: C-C motif chemokine ligand 3
-
Gene ID
- 25542
-
NCBI Accession
- NP_037157
-
UniProt
- P50229
-
Pathways
- Cellular Response to Molecule of Bacterial Origin, Autophagy