Quick Overview for MMP1 ELISA Kit (ABIN6720383)
Target
See all MMP1 ELISA KitsReactivity
Detection Method
Method Type
Detection Range
Application
Sample Type
-
-
Minimum Detection Limit
- 156 pg/mL
-
Supplier Product No.
- koa0266
-
Supplier
- Rockland
-
Purpose
- Human MMP-1 Sandwich ELISA Kit for Quantitative Detection
-
Brand
- AccuSignal™
-
Analytical Method
- Quantitative
-
Specificity
-
Expression system for standard: NS0
Immunogen sequence: F20-N469 -
Cross-Reactivity (Details)
- There is no detectable cross-reactivity with other relevant proteins.
-
Sensitivity
- < 20 pg/mL
-
Components
-
- Antibody-coated 96-well plate
- Target Protein Standard
- Detection antibody
- Detection reagent
- Diluent buffers
- Wash buffers
- Substrate Solution
- Stop solutions
- Adhesive covers
-
Material not included
- Microplate Reader capable of reading absorbance at 450nm. Incubator. Automated plate washer (optional). Pipettes and pipette tips capable of precisely dispensing 0.5 μL through 1 mL volumes of aqueous solutions. Multichannel pipettes are recommended for large amount of samples. Deionized or distilled water. 500 mL graduated cylinders. Test tubes for dilution.
-
-
-
-
Comment
-
Capture antibody and Detection antibody: monoclonal antibody from mouse, polyclonal antibody from goat
-
Sample Volume
- 100 μL
-
Plate
- Pre-coated
-
Protocol
- Useful in Sandwich ELISA for Quantitative Detection of Antigen. Aliquot 0.1 mL per well of the 10000pg/mL, 5000pg/mL, 2500pg/mL, 1250pg/mL, 625pg/mL, 312pg/mL, 156pg/mL human MMP-1 standard solutions into the precoated 96-well plate. Add 0.1 mL of the sample diluent buffer into the control well (Zero well). Add 0.1 mL of each properly diluted sample of human cell culture supernates, serum or plasma (heparin) to each empty well. It is recommended that each human MMP-1 standard solution and each sample be measured in duplicate.
-
Assay Precision
-
Intra-Assay Precision (CV%): 6.5%, 7.6%, 5.8%
Inter-Assay Precision (CV%): 8.3%, 9.4%, 7.6% -
Restrictions
- For Research Use only
-
-
-
Storage
- 4 °C,-20 °C
-
Storage Comment
- Store vials at 4°C prior to opening. Centrifuge product if not completely clear after standing at room temperature. This product is stable for 6 months at 4°C as an undiluted liquid. Dilute only prior to immediate use. For extended storage freeze at -20°C or below for 12 months. Avoid cycles of freezing and thawing.
-
Expiry Date
- 12 months
-
-
- MMP1 (Matrix Metallopeptidase 1 (Interstitial Collagenase) (MMP1))
-
Alternative Name
- MMP-1
-
Background
-
Background: Matrix metalloproteinase-1 (MMP-1) is also known as collagenase. Matrix metalloproteinases (MMPs) are zinc-dependent proteases that degrade extrMMP-1llular matrix proteins. The MMPs comprise a family of at least 20 proteolytic enzymes that play an essential role in tissue remodeling. Matrix metalloproteinase-1 (MMP-1) plays an important role in the degradation of collagen in inflammatory diseases. MMP1 (interstitial collagenase), MMP9 (gelatinase B) and MMP12 (macrophage elastase) are thought to be important in the development of emphysema. Smoking-induced MMP-1 might be important in the skin-ageing effects of tobacco smoking. The standard product used in this kit is human MMP-1 with the molecular mass of 51-53KDa. The detected MMP-1 includes zymogen and active enzyme.
Gene Full Name: matrix metallopeptidase 1
-
Gene ID
- 4312
-
NCBI Accession
- NP_001139410
-
UniProt
- P03956
Target See all MMP1 ELISA Kits
-