YBX1 ELISA Kit
Quick Overview for YBX1 ELISA Kit (ABIN7672510)
Target
See all YBX1 ELISA KitsReactivity
Detection Method
Method Type
Detection Range
Application
Sample Type
Grade
-
-
Minimum Detection Limit
- 0.313 ng/mL
-
Purpose
- Human YBX1 (Nuclease-sensitive element-binding protein 1) QuickTest ELISA Kit
-
Analytical Method
- Quantitative
-
Specificity
- Specifically binds with YBX1 , no obvious cross reaction with other analogues.
-
Sensitivity
- 0.188 ng/mL
-
Components
-
- ELISA Microplate(Dismountable)
- Lyophilized Standard
- Cap/Det Ab (Ready to use
- blue)
- TMB Substrate
- Sample Dilution Buffer
- Stop Solution
- Plate Sealer
- Product Description
-
Material not included
-
- Microplate reader (wavelength: 450nm)
- 37 °C incubator (CO2 incubator for cell culture is not recommenced.)
- Automated plate washer or multi-channel pipette/5 mL pipettor
- Precision single (0.5-10μL
- 5-50μL
- 20-200μL
- 200-1000μL) and multi-channel pipette with disposable tips(Calibration is required before use.)
- Sterile tubes and Eppendorf tubes with disposable tips
- Absorbent paper and loading slot
- Deionized or distilled water
-
-
-
-
Application Notes
- Optimal working dilution should be determined by the investigator.
-
Comment
-
Sandwich ELISA, Double Antibody
-
Sample Volume
- 50 μL
-
Assay Time
- 2 h
-
Plate
- Pre-coated
-
Protocol
- Step 1: Take out the required plate wells, add 50 µL Cap/Det Ab into each well, then add 50 µL Standard or Sample into individual well. (When adding standard or sample, the disposable tip lightly touches the liquid level. Change the disposable tips for different samples and standards.) Gently tap the plate for 10s to ensure thorough mixing then static incubate for 60 minutes at 37 °C. Washing: Wash the plate twice without immersion. Step 2: Add 100 µL HRP-Streptavidin (orange) into each well, seal the plate and static incubate for 30 minutes at 37 °C. Washing: Wash the plate five times without immersion. Step 3: Add 90 µL TMB substrate solution, seal the plate and static incubate for 10-20 minutes at 37 °C. (Accurate TMB visualization control is required.) Step 4: Add 50 µL stop solution. Read at 450nm immediately and calculate.
-
Assay Procedure
-
- Take out the required strips, add 50 µL Cap/Det Ab into each well, then add 50 µL Standard or Sample into relevant well. (When adding standard or sample, the disposable tip lightly touches the liquid level. Change the disposable tips for different samples and standards.) Gently tap the plate for 10s to ensure complete mixing then statically incubate for 60 minutes at 37 °C.
- Wash the plate twice without immersion.
- Add 100 µL HRP-Streptavidin (orange) into each well, seal the plate and statically incubate for 30 minutes at 37 °C.
- Wash the plate five times without immersion.
- Add 90 µL TMB substrate solution, seal the plate and statically incubate for 10-20 minutes at 37 °C (Accurate TMB visualization control is required.).
- Add 50 µL stop solution. Read at 450nm immediately and calculate.
-
Restrictions
- For Research Use only
-
-
-
Handling Advice
- Avoid direct light exposure to antibody solutions
-
Storage
- 4 °C
-
Storage Comment
- Store sealed Kit at 2-8° C. Do Not Cryopreserve. Store ELISA Microplate for 1 month at 2-8°C, Store for 12 month at -20°C. Put the leftover strips into a sealed foil bag with the desiccant
-
Expiry Date
- 12 months
-
-
- YBX1 (Y Box Binding Protein 1 (YBX1))
-
Alternative Name
- YBX1
-
Background
- Y-box-binding protein 1, YB-1, CCAAT-binding transcription factor I subunit A, CBF-A, DNA-binding protein B, DBPB, Enhancer factor I subunit A, EFI-A, Nuclease-sensitive element-binding protein 1, Y-box transcription factor, YBX1, NSEP1, YB1
-
UniProt
- P67809
-
Pathways
- Regulation of Muscle Cell Differentiation
Target See all YBX1 ELISA Kits
-