Phone:
+1 877 302 8632
Fax:
+1 888 205 9894 (Toll-free)
E-Mail:
orders@antibodies-online.com

IL-21 ELISA Kit

This Colorimetric ELISA kit is designed for the quantitative measurement of Human IL-21.
Catalog No. ABIN7826608
$1,264.56
Plus shipping costs $50.00
Shipping to: United States
Delivery in 12 to 14 Business Days

Quick Overview for IL-21 ELISA Kit (ABIN7826608)

Target

See all IL-21 (IL21) ELISA Kits
IL-21 (IL21) (Interleukin 21 (IL21))

Reactivity

  • 10
  • 10
  • 5
  • 3
  • 3
  • 3
  • 3
  • 2
  • 2
  • 1
  • 1
  • 1
Human

Detection Method

Colorimetric

Method Type

Sandwich ELISA

Detection Range

62.5 pg/mL - 4000 pg/mL

Application

ELISA

Sample Type

Plasma, Serum
  • Minimum Detection Limit

    62.5 pg/mL

    Purpose

    This ELISA kit applies to the in vitro quantitative determination of Human IL-21 concentrations in serum, plasma and other biological fluids.

    Analytical Method

    Quantitative

    Cross-Reactivity (Details)

    This kit recognizes Human IL-21 in samples. No significant cross-reactivity or interference between Human IL-21 and analogues was observed

    Characteristics

    Uncoated ELISA kits contain the basic components required for the ELISA experiments. For customers who have rich experience and can establish their own ELISA system, uncoated kit is an ideal choice to save costs.

    Components

    • Capture Antibody
    • Reference Standard
    • Micro ELISA pre-Plate
    • Biotinylated Detection Antibody
    • HRP Conjugate
    • Manual

    Material not included

    • Ancillary Reagents (ABIN7670776)
    • Microplate reader with 450 nm wavelength filter
    • High-precision transfer pipette
    • EP tubes
    • disposable pipette tips
    • Incubator capable of maintaining 37 °C
    • Deionized or distilled water
    • Absorbent paper
    • Loading slot
  • Sample Volume

    100 µL

    Assay Time

    1 d

    Plate

    Uncoated

    Protocol

    1. Take out the Micro ELISA pre-Plate, add 100 µL Capture antibody working solution to each well. Incubate overnight at 2-8°C.
      Discard the liquid, add 200 µL ELISA Plate Blocking Buffer to each well. Incubate for 60 min at 37°C
    2. Discard the liquid, add 100 µL standard or sample to the wells. Incubate for 90 min at 37°C
    3. Discard the liquid, immediately add 100 µL Biotinylated Detection Ab working solution to each well. Incubate for 60 min at 37°C
    4. Aspirate and wash the plate 3 times
    5. Add 100 µL HRP conjugate working solution. Incubate foe 30 min at 37°C. Aspirate and wash the plate for 5 times.
    6. Add 90 µL Substrate Reagent. Incubate for 15 min at 37°C
    7. Add 50 µL Stop Solution
    8. Read the plate at 450 nm immediately. Calculation of the results

    Assay Precision

    Both intra-CV and inter-CV are < 10%

    Restrictions

    For Research Use only
  • Storage

    -20 °C

    Storage Comment

    Store all unopend components at -20°C for up to 12 months.

    Expiry Date

    12 months
  • Target See all IL-21 (IL21) ELISA Kits

    IL-21 (IL21) (Interleukin 21 (IL21))

    Alternative Name

    IL-21

    Background

    IL21,Za11

    UniProt

    Q9HBE4

    Pathways

    JAK-STAT Signaling, Regulation of Leukocyte Mediated Immunity, Positive Regulation of Immune Effector Process, Production of Molecular Mediator of Immune Response