Phone:
+1 877 302 8632
Fax:
+1 888 205 9894 (Toll-free)
E-Mail:
orders@antibodies-online.com

Factor VIII CLIA Kit

Human Factor VIII ELISA Kit, Chemiluminescent assay for quantification of Human Factor VIII.
Catalog No. ABIN8077009
$1,205.77
Plus shipping costs $50.00
96 tests
Shipping to: United States
Delivery in 8 to 13 Business Days

Quick Overview for Factor VIII CLIA Kit (ABIN8077009)

Target

See all Factor VIII (F8) CLIA Kits
Factor VIII (F8) (Coagulation Factor VIII (F8))

Reactivity

  • 16
  • 11
  • 7
  • 7
  • 3
  • 3
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
Human

Detection Method

Chemiluminescent

Method Type

Sandwich ELISA

Detection Range

13.7 pg/mL - 10000 pg/mL

Application

ELISA

Sample Type

Plasma
  • Minimum Detection Limit

    13.7 pg/mL

    Purpose

    Human Coagulation Factor VIII (F8) CLIA Kit for detecting F8 in plasma.

    Analytical Method

    Quantitative

    Sensitivity

    4.9 pg/mL

    Components

    • Pre-coated, ready to use 96-well strip plate
    • Standar
    • Detection Reagent A
    • Detection Reagent B
    • Substrate A
    • Substrate B
    • Assay Diluent A
    • Assay Diluent B
    • Wash Buffer (30x concentrate)
    • Standard Diluent
    • Plate Sealer
    • Instruction Manual

    Material not included

    • Microplate Reader with 450 nm filter
    • Single or multi-channel pipettes with high precision and disposable tips
    • Microcentrifuge tubes
    • Deionized or distilled watter
    • Absorbent paper for blotting the microplate
    • Container for wash solution
    • 0.01 M (or 1x) Phosphate Buffered Saline (PBS), ph 7.0-7.2
  • Application Notes

    Optimal working dilution should be determined by the investigator.

    Comment

    This product is tested and assembled before shipping to ensure that it meets its quality specifications. All kits are tested to confirm that they fall within their defined Inter- and Intra- assay coefficient of variation.

    Sample Volume

    100 μL

    Assay Time

    3 h

    Plate

    Pre-coated

    Assay Precision

    Intra-Assay: CV<10%,
    Inter-Assay: CV<12%

    Restrictions

    For Research Use only
  • Storage

    4 °C

    Storage Comment

    4°C for one month, Long term: see manual.

    Expiry Date

    12 months
  • Target See all Factor VIII (F8) CLIA Kits

    Factor VIII (F8) (Coagulation Factor VIII (F8))

    Alternative Name

    Coagulation Factor VIII

    Background

    Gene Aliases: FVIII, AHF, HEMA, F8B, F8C, Antihemophilic Globulin, Hemophilia A, Anti-Hemophilic Factor A, FVIII Procoagulant Component, F8 Protein

    UniProt

    P00741
You are here:
Chat with us!