Phone:
+1 877 302 8632
Fax:
+1 888 205 9894 (Toll-free)
E-Mail:
orders@antibodies-online.com

Destrin ELISA Kit

This Colorimetric ELISA kit is designed for the quantitative measurement of Human Destrin.
Catalog No. ABIN8078120
$840.00
Plus shipping costs $50.00
96 tests
Shipping to: United States
Delivery in 8 to 13 Business Days

Quick Overview for Destrin ELISA Kit (ABIN8078120)

Target

See all Destrin (DSTN) ELISA Kits
Destrin (DSTN) (Destrin (Actin Depolymerizing Factor) (DSTN))

Reactivity

  • 4
  • 2
  • 2
  • 1
  • 1
  • 1
Human

Detection Method

Colorimetric

Method Type

Sandwich ELISA

Detection Range

0.156 ng/mL - 10 ng/mL

Application

ELISA

Sample Type

Plasma, Serum, Tissue Homogenate
  • Minimum Detection Limit

    0.156 ng/mL

    Purpose

    Human Destrin (DSTN) ELISA Kit for detecting DSTN in serum, plasma, tissue homogenates

    Analytical Method

    Quantitative

    Sensitivity

    0.056 ng/mL

    Components

    • Pre-coated, ready to use 96-well strip plate
    • Standar
    • Detection Reagent A
    • Detection Reagent B
    • TMB Substrate
    • Stop Solution
    • Assay Diluent A
    • Assay Diluent B
    • Wash Buffer (30x concentrate)
    • Standard Diluent
    • Plate Sealer
    • Instruction Manual

    Material not included

    • Microplate Reader with 450 nm filter
    • Single or multi-channel pipettes with high precision and disposable tips
    • Microcentrifuge tubes
    • Deionized or distilled watter
    • Absorbent paper for blotting the microplate
    • Container for wash solution
    • 0.01 M (or 1x) Phosphate Buffered Saline (PBS), ph 7.0-7.2
  • Application Notes

    Optimal working dilution should be determined by the investigator.

    Comment

    This product is tested and assembled before shipping to ensure that it meets its quality specifications. All kits are tested to confirm that they fall within their defined Inter- and Intra- assay coefficient of variation.

    Sample Volume

    100 μL

    Assay Time

    3 h

    Plate

    Pre-coated

    Assay Precision

    Intra-Assay: CV<10%,
    Inter-Assay: CV<12%

    Restrictions

    For Research Use only
  • Storage

    4 °C

    Storage Comment

    4°C for one month, Long term: see manual.

    Expiry Date

    12 months
  • Target See all Destrin (DSTN) ELISA Kits

    Destrin (DSTN) (Destrin (Actin Depolymerizing Factor) (DSTN))

    Alternative Name

    Destrin

    Background

    Gene Aliases: ADF, ACTDP, Actin Depolymerizing Factor, Actin Binding Protein

    Gene ID

    11034

    UniProt

    P60981