Macrophage Scavenger Receptor 1 ELISA Kit

Human Macrophage Scavenger Receptor 1 ELISA Kit, Colorimetric assay for quantification of Human Macrophage Scavenger Receptor 1.
Catalog No. ABIN8083135
$806.08
Plus shipping costs $50.00
96 tests
Shipping to: United States
Delivery in 8 to 13 Business Days

Quick Overview for Macrophage Scavenger Receptor 1 ELISA Kit (ABIN8083135)

Target

See all Macrophage Scavenger Receptor 1 (MSR1) ELISA Kits
Macrophage Scavenger Receptor 1 (MSR1)

Reactivity

  • 15
  • 5
  • 1
Human

Detection Method

Colorimetric

Method Type

Sandwich ELISA

Detection Range

0.312 ng/mL - 20 ng/mL

Application

ELISA

Sample Type

Cell Culture Supernatant, Cell Lysate, Tissue Homogenate
  • Minimum Detection Limit

    0.312 ng/mL

    Purpose

    Human Macrophage Scavenger Receptor 1 (MSR1) ELISA Kit for detecting MSR1 in tissue homogenates, cell lysates, cell culture supernates

    Analytical Method

    Quantitative

    Sensitivity

    0.125 ng/mL

    Components

    • Pre-coated, ready to use 96-well strip plate
    • Standar
    • Detection Reagent A
    • Detection Reagent B
    • TMB Substrate
    • Stop Solution
    • Assay Diluent A
    • Assay Diluent B
    • Wash Buffer (30x concentrate)
    • Standard Diluent
    • Plate Sealer
    • Instruction Manual

    Material not included

    • Microplate Reader with 450 nm filter
    • Single or multi-channel pipettes with high precision and disposable tips
    • Microcentrifuge tubes
    • Deionized or distilled watter
    • Absorbent paper for blotting the microplate
    • Container for wash solution
    • 0.01 M (or 1x) Phosphate Buffered Saline (PBS), ph 7.0-7.2
  • Application Notes

    Optimal working dilution should be determined by the investigator.

    Comment

    This product is tested and assembled before shipping to ensure that it meets its quality specifications. All kits are tested to confirm that they fall within their defined Inter- and Intra- assay coefficient of variation.

    Sample Volume

    100 μL

    Assay Time

    3 h

    Plate

    Pre-coated

    Assay Precision

    Intra-Assay: CV<10%,
    Inter-Assay: CV<12%

    Restrictions

    For Research Use only
  • Storage

    4 °C

    Storage Comment

    4°C for one month, Long term: see manual.

    Expiry Date

    12 months
  • Target See all Macrophage Scavenger Receptor 1 (MSR1) ELISA Kits

    Macrophage Scavenger Receptor 1 (MSR1)

    Alternative Name

    Macrophage Scavenger Receptor 1

    Background

    Gene Aliases: CD204, MSR1, SCARA1, SR-A, PhSR1, PhSR2, Macrophage acetylated LDL receptor I and II, Scavenger receptor class A member 1

    Gene ID

    4481

    UniProt

    P21757
You are here:
Chat with us!