MIF ELISA Kit

MIF Reactivity: Mouse Colorimetric Sandwich ELISA 0.156-10 ng/mL
Catalog No. ABIN955930
  • Target See all MIF ELISA Kits
    MIF (Macrophage Migration Inhibitory Factor (Glycosylation-Inhibiting Factor) (MIF))
    Reactivity
    • 7
    • 4
    • 3
    • 3
    • 2
    • 2
    • 2
    • 2
    • 2
    • 2
    • 2
    • 1
    • 1
    • 1
    • 1
    Mouse
    Detection Method
    Colorimetric
    Method Type
    Sandwich ELISA
    Detection Range
    0.156-10 ng/mL
    Minimum Detection Limit
    0.156 ng/mL
    Application
    ELISA
    Purpose
    The kit is a sandwich enzyme immunoassay for the in vitro quantitative measurement of mouse MIF in serum, plasma and other biological fluids.
    Analytical Method
    Quantitative
    Specificity
    This assay has high sensitivity and excellent specificity for detection of mouse MIF. No significant cross- reactivity or interference was observed.
    Sensitivity
    The minimum detectable dose of mouse MIF is typically less than 0.041 ng/mL.
    The Sensitivity of this assay, or Lower Limit of Detection (LLD) was defined as the lowest protein concentration that could be differentiated from zero. It was determined the mean O.D. Value of 20 replicates of the zero calibrator plus three standard deviations.
    Characteristics
    The microtiter plate provided in this kit has been pre-coated with an antibody specific to MIF. Calibrators or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated polyclonal antibody preparation specific for MIF. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. Then a TMB substrate solution is added to each well. Only those wells that contain MIF, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of a sulfuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450 nm +/- 2 nm. The concentration of MIF in the samples is then determined by comparing the O.D. of the samples to the calibration curve.
    Components
    Pre-coated, ready to use 96-well strip plate (1x)
    Calibrator (lyophilized) (2x)
    Calibrator Diluent (1 x 20 mL)
    Detection Reagent A (1 x 120 µL)
    Detection Reagent B (1 x 120 µL)
    Assay Diluent A (2X concentrate) (1 x 6 mL)
    Assay Diluent B (2X concentrate) (1 x 6 mL)
    TMB Substrate (1 x 9 mL)
    Stop Solution (1 x 6 mL)
    Wash Buffer (30X concentrate) (1 x 20 mL)
    Plate sealer for 96 wells (4x).
    Material not included
    1. Microplate reader with 450 +/- 10 nm filter.
    2. Precision single and multi-channel pipettes and disposable tips.
    3. Eppendorf Tubes for diluting samples.
    4. De-ionized or distilled water.
    5. Absorbent paper for blotting the microtiter plate.
    6. Container for Wash Solution.
    Featured
    Discover our best selling MIF ELISA Kit
    Top Product
    Discover our top product MIF ELISA Kit
  • Comment

    The calibration curve concentrations used for the ELISA's were 10 ng/mL, 5 ng/mL, 2.5 ng/mL, 1.25 ng/mL, 0.625 ng/mL, 0.312 ng/mL, 0.156 ng/mL.

    Plate
    Pre-coated
    Calculation of Results

    Average the duplicate readings for each calibrator, control, and samples and subtract the average zero calibrator optical density. Create a calibration curve by reducing the data using computer software capable of generating a four parameter logistic (4-PL) curve-fit. As an alternative, construct a calibration curve by plotting the mean absorbance for each calibrator on the x-axis against the concentration on the y-axis and draw a best fit curve through the points on the graph. The data may be linearized by plotting the log of the MIF concentrations versus the log of the O.D. and the best fit line can be determined by regression analysis. It is recommended to use some related software to do this calculation. This procedure will produce an adequate but less precise fit of the data. If samples have been diluted, the concentration read from the calibration curve must be multiplied by the dilution factor.

    Restrictions
    For Research Use only
  • Storage
    -20 °C
    Storage Comment
    All the reagents should be kept according to the labels on vials. The Calibrator, Detection Reagent A, Detection Reagent B and the 96-well strip plate should be stored at -20° C upon being received. The unused strips should be kept in a sealed bag with the desiccant provided to minimize exposure to damp air. Opened test kits will remain stable until the expiration date shown, provided it is stored as prescribed above.
    Expiry Date
    The expiry date is stated on the label.
  • Target See all MIF ELISA Kits
    MIF (Macrophage Migration Inhibitory Factor (Glycosylation-Inhibiting Factor) (MIF))
    Alternative Name
    MIF (MIF Products)
    Synonyms
    mif ELISA Kit, Mif ELISA Kit, gif ELISA Kit, glif ELISA Kit, mmif ELISA Kit, LOC100136498 ELISA Kit, LOC100284350 ELISA Kit, LOC100284546 ELISA Kit, GIF ELISA Kit, Glif ELISA Kit, GLIF ELISA Kit, MMIF ELISA Kit, macrophage migration inhibitory factor L homeolog ELISA Kit, macrophage migration inhibitory factor ELISA Kit, macrophage migration inhibitory factor (glycosylation-inhibiting factor) ELISA Kit, mif.L ELISA Kit, mif ELISA Kit, MIF ELISA Kit, Mif ELISA Kit, PHATRDRAFT_49660 ELISA Kit, LOC100136498 ELISA Kit, cl405_1 ELISA Kit, LOC100284546 ELISA Kit
    Pathways
    Regulation of Systemic Arterial Blood Pressure by Hormones, Positive Regulation of Immune Effector Process, Production of Molecular Mediator of Immune Response, Regulation of Carbohydrate Metabolic Process, Feeding Behaviour, Smooth Muscle Cell Migration, Negative Regulation of intrinsic apoptotic Signaling