Phone:
+1 877 302 8632
Fax:
+1 888 205 9894 (Toll-free)
E-Mail:
orders@antibodies-online.com

GLP-2 ELISA Kit

This Colorimetric ELISA kit is designed for the quantitative measurement of Mouse GLP-2.
Catalog No. ABIN956057
$1,506.46
Plus shipping costs $50.00
96 tests
Shipping to: United States
Delivery in 11 to 17 Business Days

Quick Overview for GLP-2 ELISA Kit (ABIN956057)

Target

See all GLP-2 ELISA Kits
GLP-2 (Glucagon-like peptide 2 (GLP-2))

Reactivity

  • 6
  • 5
  • 4
  • 3
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
Mouse

Detection Method

Colorimetric

Method Type

Competition ELISA

Application

ELISA
  • Purpose

    The Mouse GLP-2 (Glucagon-Like Peptide-2) EIA is for the quantitative determination of GLP-2 in mouse serum or plasma.

    Analytical Method

    Quantitative

    Specificity

    Does not cross-react with mouse Glucagon and mouse GLP-1 within the range of 300 pmol/mL.

    Characteristics

    The proglucagon gene is expressed in both pancreatic A cells and intestinal L cells. Tissue-specific post-translational processing of proglucagon by the prohormone convertase produces the different proglucagon derived peptides (PGDPs) in both pancreas and intestine. The most notable pancreatic PGDP is glucagon, whereas the L cells produce several structurally related peptides, including glucagon-like peptide (GLP)-1 and GLP-2, as well as glicentin and oxyntomodulin, which contain glucagon sequence in their molecules. Among PGDPs, GLP-2 has recently been found to show intestinal epithelial proliferation. Advantages of this assay include sensitive quantification, high specificity, no interference from other components in serum or plasma and no sample pretreatment. The Mouse GLP-2 Calibrator is a highly purified synthetic product.This EIA kit is based on a competitive enzyme immunoassay using a highly specific antibody to rat GLP-2 (strong cross- reactivity to mouse GLP-2) and a biotin/avidin-affinity system. The 96-well plate is coated with goat anti-rabbit IgG antibody. Mouse GLP-2 Calibrator or samples, biotinylated Rat GLP-2 and anti-Rat GLP-2 polyclonal antibody are added to the wells for a competitive immuno-reaction. After incubation and plate rinsing, HRP-Labeled Streptoavidins (SA-HRP) are added to form HRP-labeled streptoavidin-biotinylated Rat GLP-2-antibody complexes on the surface of the wells. Finally, HRP-enzyme activity is determined by o-Phenylenediamine dihydrochoride (OPD), and the concentration of Mouse GLP-2 is calculated.

    Components

    1. Antibody-Coated Plate MTP: 1 plate (96-well) Goat Anti-rabbit IgG
    2. GLP-2 Calibrator Lyophilized: 1 vial (50 ng/vial) Synthetic Mouse GLP-2
    3. Labeled Antigen Lyophilized: 1 vial Biotinylated Rat GLP-2
    4. GLP-2 Antibody Liquid: 1 bottle (6 mL) Rabbit anti-Rat GLP-2
    5. SA-HRP Solution Liquid: 1 bottle (12 mL) HRP-labeled streptoavidin
    6. Substrate Buffer Liquid: 1 bottle (26 mL) 0.015% Hydrogen peroxide
    7. OPD Tablet: 2 tablets o-Phenylenediamine dihydrochloride
    8. Stop Solution Liquid: 1 bottle (12 mL) 2 N H2SO4
    9. Buffer Solution Liquid: 1 bottle (25 mL) Phosphate buffer
    10. Wash Solution Liquid: 1 bottle (50 mL) Concentrated saline Concentrate
    11. Plate Seal: 3 sheets

    Material not included

    Photometer for microtiter plate (plate reader), which can read absorbance up to 2.5 at 490 nm
    Rotator for microtiter plate
    Washing device for microtiter plate and dispenser with aspiration system
    Micropipettes, multi-channel pipettes for 8 wells or 12 wells and their tips
    Test tubes for preparation of Calibrator Solution
    Graduated cylinder (1,000 mL)
    Distilled water or de-ionized water
  • Plate

    Pre-coated

    Reagent Preparation

    1. Preparation of Calibrator Solutions: Reconstitute the GLP-2 Calibrator (lyophilized Mouse GLP-2, 50 ng/vial) with 0.5 mL of Buffer Solution, giving a 100 ng/mL Calibrator Solution after reconstitution. 0.1 mL of the reconstituted Calibrator Solution is diluted with 0.2 mL of Buffer Solution to yield a 33.33 ng/mL Calibrator Solution. Repeat the serial dilution to make Calibrator Solutions at 11.11, 3.704, 1.235, and 0.412. Buffer Solution is used as the zero calibrator (0 ng/mL). Note: Calibrator Solution must be prepared immediately before assay. Use clean test tubes or vessels. In the case of multiple assays, the reconstituted stock Calibrator (100 ng/mL) should be stored at -30°C.

      2. Preparation of Labeled Antigen: Reconstitute Labeled Antigen with 9 mL of Buffer Solution. Note: Labeled Antigen must be prepared immediately before assay. Use clean test tubes or vessels. In the case of multiple assays, the reconstituted labeled Antigen solution should be stored at -30C.

      3. Preparation of Substrate Solution: Dissolve one OPD Tablet in 12 mL of Substrate Buffer. Note: Substrate Solution must be prepared immediately before assay. Use clean test tubes or vessels.

      4. Preparation of Wash Solution: Dilute 50 mL of Wash Solution Concentrate to 1,000 mL with distilled or de-ionized water. Diluted Wash Solution is stable for 6 months at 4°C. Note: During storage of the Wash Solution Concentrate at 4°C, precipitates may be observed, however, they will dissolve when diluted.

      5. Other reagents are ready for use.

    Assay Procedure

    1. Warm the reagents and samples to room temperature (20-30°C) before beginning the test.
      2. Add 75 µL each of Labeled Antigen solution into the wells. Then add 25 µL of the prepared Calibrator Solutions (0, 0.412, 1.235, 3.704, 11.11, 33.33, 100 ng/mL) or samples. Next, add 50 µL of GLP-2 Antibody to the wells.
      3. Cover the plate with the Plate Seal and incubate at 4°C overnight (16 -18 hours). Plate rotator not yet needed.
      4. Remove the Plate Seal and aspirate the solution in the wells. Wash the wells three times with approximately 0.35 mL/well of Wash Solution.
      5. Pipette 100 µL of SA-HRP Solution into each of the wells.
      6. Cover the plate with a Plate Seal and incubate at room temperature for 1 hour. During the incubation, the plate should be rotated on a plate rotator.
      7. Dissolve 1 OPD Tablet with 12 mL of Substrate Buffer.
      8. Remove the Plate Seal, aspirate and wash the wells five times with approximately 0.3 mL/well of Wash Solution.
      9. Add 100 µL of Substrate Solution into the wells, cover the plate with a Plate Seal and incubate for 30 minutes at room temperature.
      10. Add 100 µL of Stop Solution into the wells to stop the reaction.
      11. Read the optical absorbance of the wells at 492 nm. The optical absorbance of reaction solution in wells should be read as soon as possible after stopping the color reaction. Note: Perform all determinations in duplicate.

    Calculation of Results

    Calculate mean absorbance values of wells containing the Calibrators and plot a calibration curve on semilogarithmic graph paper (abscissa: concentration of Calibrators, ordinate: absorbance values of Calibrators). Use the calibration curve to read GLP-2 concentrations in samples from the corresponding absorbance values. When a sample value exceeds 100 ng/mL, it must be diluted with Buffer Solution and re-assayed until the sample value is within the assay range.

    Restrictions

    For Research Use only
  • Storage

    4 °C
  • Target See all GLP-2 ELISA Kits

    GLP-2 (Glucagon-like peptide 2 (GLP-2))

    Alternative Name

    GLP-2
You are here:
Chat with us!