SAA1 ELISA Kit

This Colorimetric ELISA kit is designed for the quantitative measurement of Rabbit SAA1.
Catalog No. ABIN2538930
$981.50
Plus shipping costs $50.00
Shipping to: United States
Delivery in 10 to 20 Business Days

Quick Overview for SAA1 ELISA Kit (ABIN2538930)

Target

See all SAA1 ELISA Kits
SAA1 (Serum Amyloid A1 (SAA1))

Reactivity

  • 7
  • 5
  • 3
  • 2
  • 2
  • 1
  • 1
Rabbit

Detection Method

Colorimetric

Method Type

Sandwich ELISA

Detection Range

0.156 ng/mL - 10 ng/mL

Application

ELISA

Sample Type

Plasma, Serum
  • Minimum Detection Limit

    0.156 ng/mL

    Purpose

    This kit is based on sandwich enzyme-linked immuno-sorbent assay technology.

    Analytical Method

    Quantitative

    Sensitivity

    < 0.07 ng/mL

    Components

    The kit components listed are for reference only. The product manual may differ slightly. The product should be used as stated on the product manual included and delivered together with the product.
    • Pre-coated 96-Well Microplate
    • Standard
    • Standard Diluent Buffer
    • Wash Buffer
    • Detection Reagent A
    • Detection Reagent B
    • Diluent A
    • Diluent B
    • TMB Substrate
    • Stop Solution
    • Plate Sealer

    Material not included

    • 37 °C incubator
    • Multi and single channel pipettes and sterile pipette tips
    • Squirt bottle or automated microplate washer
    • 1.5 mL tubes
    • Distilled water
    • Absorbent filter papers
    • 100 mL and 1 liter graduated cylinders
    • Microplate reader (wavelength: 450 nm)
    • ELISA Shaker
  • Sample Volume

    100 µL

    Plate

    Pre-coated

    Protocol

    This kit is based on sandwich enzyme-linked immuno-sorbent assay technology. An antibody is pre-coated onto a 96-well plate. Standards, test samples, and biotin-conjugated reagent are added to the wells and incubated. The HRP-conjugated reagent is then added, and the whole plate is incubated. Unbound conjugates are removed using wash buffer at each stage. TMB substrate is used to quantify the HRP enzymatic reaction. After TMB substrate is added, only wells that contain sufficient SAA1 will produce a blue coloured product, which then changes to yellow after adding the acidic stop solution. The intensity of the yellow colour is proportional to the SAA1 amount bound on the plate. The Optical Density (OD) is measured spectrophotometrically at 450 nm in a microplate reader, from which the concentration of SAA1 can be calculated.

    Reagent Preparation

    This procedure is provided for reference only. The product manual may differ slightly. The product should be used as stated on the product manual included and delivered together with the product.

    • 1) Standard: Prepare the standard with the recommended volume of Standard Diluent Buffer, to make the standard solution. Then use the Standard Diluent buffer to carry out serial dilutions of the standard solution, as instructed in the Protocol.
    • 2) Wash Buffer: Dilute the concentrated Wash Buffer with distilled water, as instructed in the Protocol.
    • 3) Detection Reagent Preparation: Calculate the total volume of working solution required. Dilute Detection Reagent A and Detection Reagent B with Diluent A and Diluent B, respectively, at 1:100.

    Assay Procedure

    This procedure is provided for reference only. The product manual may differ slightly. The product should be used as stated on the product manual included and delivered together with the product.

    • 1) Set standard, test samples and control wells.
    • 2) Aliquot 100 μL of diluted standard into the standard wells.
    • 3) Aliquot 100 μL of Standard Diluent buffer into control (zero) well.
    • 4) Aliquot 100 μL of diluted samples into the sample wells. Incubate for 1 hr at 37 °C.
    • 5) Aliquot 100 μL of Detection Reagent A to each well. Incubate for 1 hr at 37 °C.
    • 6) Wash 3 times.
    • 7) Aliquot 100 μL of Detection Reagent B to each well. Incubate for 30 mins at 37 °C.
    • 8) Wash 5 times.
    • 9) Aliquot 90 μL of TMB Substrate to each well. Incubate for 10-20 mins at 37 °C.
    • 10) Aliquot 50 μL of Stop Solution.
    • 11) Measure the OD at 450 nm.

    Calculation of Results

    For calculation, average the O.D.450 duplicate readings for each reference standard and each sample and substract the average control (zero) O.D.450 reading. The standard curve can be plotted as the relative O.D.450 of each reference standard solution [Y] vs. the respective concentration of each standard solution (X). The SAA1 concentration of the samples can be interpolated from the standard curve.

    Assay Precision

    Intra-assay Precision (Precision within an assay): 3 samples with low, medium and high levels of Serum Amyloid A (SAA) were were tested 20 times on one plate, respectively.

    Inter-assay Precision (Precision between assays): 3 samples with low, medium and high levels of Serum Amyloid A (SAA) were tested on 3 different plates, 8 replicates in each plate.

    CV (%) = (Standard Deviation / mean) x 100

    Intra-Assay: CV<10%

    Inter-Assay: CV<12%

    Restrictions

    For Research Use only
  • Storage

    4 °C

    Storage Comment

    Shipped at 4°C. Upon receipt, store the kit according to the storage instruction in the kit's manual.The stability of the kit is determined by the rate of activity loss. The loss rate is less than 5% within the expiration date under appropriate storage conditions. To minimize performance fluctuations, operation procedures and lab conditions should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same user throughout.

    Expiry Date

    6 months
  • Target See all SAA1 ELISA Kits

    SAA1 (Serum Amyloid A1 (SAA1))

    Alternative Name

    Serum Amyloid A-1 Protein

    Gene ID

    100009168

    UniProt

    P53614

    Pathways

    Toll-Like Receptors Cascades
You are here:
Chat with us!