IL-2 CLIA Kit
Quick Overview for IL-2 CLIA Kit (ABIN5655867)
Target
See all IL-2 (IL2) CLIA KitsReactivity
Detection Method
Method Type
Detection Range
Application
Sample Type
-
-
Minimum Detection Limit
- 2.74 pg/mL
-
Purpose
- Human Interleukin 2 (IL2) CLIA Kit for detecting IL2 in serum, plasma, tissue homogenates, cell lysates, cell culture supernates
-
Analytical Method
- Quantitative
-
Specificity
- This assay has high sensitivity and excellent specificity for detection of Interleukin 2 (IL2). No significant cross-reactivity or interference between Interleukin 2 (IL2) and analogues was observed.
-
Sensitivity
- 0.99 pg/mL
-
Components
-
- Pre-coated, ready to use 96-well strip plate
- Standar
- Detection Reagent A
- Detection Reagent B
- Substrate A
- Substrate B
- Assay Diluent A
- Assay Diluent B
- Wash Buffer (30x concentrate)
- Standard Diluent
- Plate Sealer
- Instruction Manual
-
Material not included
-
- Microplate Reader with 450 nm filter
- Single or multi-channel pipettes with high precision and disposable tips
- Microcentrifuge tubes
- Deionized or distilled watter
- Absorbent paper for blotting the microplate
- Container for wash solution
- 0.01 M (or 1x) Phosphate Buffered Saline (PBS), ph 7.0-7.2
-
-
-
-
Application Notes
- Optimal working dilution should be determined by the investigator.
-
Comment
-
This product is tested and assembled before shipping to ensure that it meets its quality specifications. All kits are tested to confirm that they fall within their defined Inter- and Intra- assay coefficient of variation.
-
Sample Volume
- 100 μL
-
Assay Time
- 3 h
-
Plate
- Pre-coated
-
Protocol
- The microplate provided in this kit has been pre-coated with an antibody specific to Interleukin 2 (IL2). Standards or samples are then added to the appropriate microplate wells with a biotin-conjugated antibody specific to Interleukin 2 (IL2). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. Then the mixture of substrate A and B is added to generate glow light emission kinetics. Upon plate development, the intensity of the emitted light is proportional to the Interleukin 2 (IL2) level in the sample or standard.,
-
Assay Precision
-
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Interleukin 2 (IL2) were tested 20 times on one plate, respectively
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Interleukin 2 (IL2) were tested on 3 different plates, 8 replicates in each plate. CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12% -
Restrictions
- For Research Use only
-
-
-
Handling Advice
- Do not allow to contact skin or eyes. Calibrators, controls and specimen samples should be assayed in duplicate. Once the procedure has been started, all steps should be completed without interruption.
-
Storage
- 4 °C,-20 °C
-
Storage Comment
- -20°C. Bring all reagents to room temperature before beginning test. The kit may be stored at 4°C for immediate use within two days upon arrival. Reseal any unused strips with desiccant pack. Minimize freeze/thaw cycles.
-
Expiry Date
- 12 months
-
-
- IL-2 (IL2) (Interleukin 2 (IL2))
-
Alternative Name
- Interleukin 2
-
Background
- Gene Aliases: TCGF, Lymphokine, T-Cell Growth Factor, Aldesleukin
-
Gene ID
- 3558
-
UniProt
- P60568
-
Pathways
- JAK-STAT Signaling, Regulation of Leukocyte Mediated Immunity, Positive Regulation of Immune Effector Process, Production of Molecular Mediator of Immune Response, Activated T Cell Proliferation
Target See all IL-2 (IL2) CLIA Kits
-