Phone:
+1 877 302 8632
Fax:
+1 888 205 9894 (Toll-free)
E-Mail:
orders@antibodies-online.com

STAT4 ELISA Kit

This Colorimetric ELISA kit is designed for the quantitative measurement of Human, Mouse and Rat STAT4.
Catalog No. ABIN5658798
$1,056.23
Plus shipping costs $50.00
96 tests
Shipping to: United States
Delivery in 8 to 13 Business Days

Quick Overview for STAT4 ELISA Kit (ABIN5658798)

Target

See all STAT4 ELISA Kits
STAT4 (Signal Transducer and Activator of Transcription 4 (STAT4))

Reactivity

  • 23
  • 13
  • 11
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
Human, Mouse, Rat

Detection Method

Colorimetric

Method Type

Sandwich ELISA

Detection Range

0.312 ng/mL - 20 ng/mL

Application

ELISA

Sample Type

Cell Culture Supernatant, Cell Lysate, Tissue Homogenate
  • Minimum Detection Limit

    0.312 ng/mL

    Purpose

    Human/Mouse/Rat Signal Transducer And Activator Of Transcription 4 (STAT4) ELISA Kit for detecting STAT4 in tissue homogenates, cell lysates, cell culture supernates

    Analytical Method

    Quantitative

    Specificity

    This assay has high sensitivity and excellent specificity for detection of Signal Transducer And Activator Of Transcription 4 (STAT4). No significant cross-reactivity or interference between Signal Transducer And Activator Of Transcription 4 (STAT4) and analogues was observed.

    Sensitivity

    0.122 ng/mL

    Components

    • Pre-coated, ready to use 96-well strip plate
    • Standar
    • Detection Reagent A
    • Detection Reagent B
    • TMB Substrate
    • Stop Solution
    • Assay Diluent A
    • Assay Diluent B
    • Wash Buffer (30x concentrate)
    • Standard Diluent
    • Plate Sealer
    • Instruction Manual

    Material not included

    • Microplate Reader with 450 nm filter
    • Single or multi-channel pipettes with high precision and disposable tips
    • Microcentrifuge tubes
    • Deionized or distilled watter
    • Absorbent paper for blotting the microplate
    • Container for wash solution
    • 0.01 M (or 1x) Phosphate Buffered Saline (PBS), ph 7.0-7.2
  • Application Notes

    Optimal working dilution should be determined by the investigator.

    Comment

    This product is tested and assembled before shipping to ensure that it meets its quality specifications. All kits are tested to confirm that they fall within their defined Inter- and Intra- assay coefficient of variation.

    Sample Volume

    100 μL

    Assay Time

    3 h

    Plate

    Pre-coated

    Protocol

    The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Signal Transducer And Activator Of Transcription 4 (STAT4). Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated antibody specific to Signal Transducer And Activator Of Transcription 4 (STAT4). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Signal Transducer And Activator Of Transcription 4 (STAT4), biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Signal Transducer And Activator Of Transcription 4 (STAT4) in the samples is then determined by comparing the O.D. of the samples to the standard curve.

    Assay Precision

    Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Signal Transducer And Activator Of Transcription 4 (STAT4) were tested 20 times on one plate, respectively
    Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Signal Transducer And Activator Of Transcription 4 (STAT4) were tested on 3 different plates, 8 replicates in each plate. CV(%) = SD/meanX100
    Intra-Assay: CV<10%
    Inter-Assay: CV<12%

    Restrictions

    For Research Use only
  • Handling Advice

    The Stop Solution is acidic. Do not allow to contact skin or eyes. Calibrators, controls and specimen samples should be assayed in duplicate. Once the procedure has been started, all steps should be completed without interruption.

    Storage

    4 °C,-20 °C

    Storage Comment

    -20°C. Bring all reagents to room temperature before beginning test. The kit may be stored at 4°C for immediate use within two days upon arrival. Reseal any unused strips with desiccant pack. Minimize freeze/thaw cycles.

    Expiry Date

    12 months
  • Target See all STAT4 ELISA Kits

    STAT4 (Signal Transducer and Activator of Transcription 4 (STAT4))

    Alternative Name

    Signal Transducer And Activator Of Transcription 4

    Background

    Gene Aliases:

    Gene ID

    6775

    UniProt

    Q14765

    Pathways

    JAK-STAT Signaling
You are here:
Chat with us!