CD63 CLIA Kit

Human CD63 ELISA Kit, Chemiluminescent assay for quantification of Human CD63.
Catalog No. ABIN5659139
$1,260.69
Plus shipping costs $50.00
96 tests
Shipping to: United States
Delivery in 8 to 13 Business Days

Quick Overview for CD63 CLIA Kit (ABIN5659139)

Target

See all CD63 CLIA Kits
CD63

Reactivity

  • 18
  • 6
  • 5
  • 4
  • 1
  • 1
Human

Detection Method

Chemiluminescent

Method Type

Sandwich ELISA

Detection Range

13.7 pg/mL - 10000 pg/mL

Application

ELISA

Sample Type

Cell Culture Supernatant, Cell Lysate, Plasma, Serum, Tissue Homogenate
  • Minimum Detection Limit

    13.7 pg/mL

    Purpose

    Human Tetraspanin 30Cluster of Differentiation 63 (CD63) CLIA Kit for detecting CD63 in serum, plasma, tissue homogenates, cell lysates, cell culture supernates

    Analytical Method

    Quantitative

    Specificity

    This assay has high sensitivity and excellent specificity for detection of Tetraspanin 30 (TSPAN30). No significant cross-reactivity or interference between Tetraspanin 30 (TSPAN30) and analogues was observed.

    Sensitivity

    5.1 pg/mL

    Components

    • Pre-coated, ready to use 96-well strip plate
    • Standar
    • Detection Reagent A
    • Detection Reagent B
    • Substrate A
    • Substrate B
    • Assay Diluent A
    • Assay Diluent B
    • Wash Buffer (30x concentrate)
    • Standard Diluent
    • Plate Sealer
    • Instruction Manual

    Material not included

    • Microplate Reader with 450 nm filter
    • Single or multi-channel pipettes with high precision and disposable tips
    • Microcentrifuge tubes
    • Deionized or distilled watter
    • Absorbent paper for blotting the microplate
    • Container for wash solution
    • 0.01 M (or 1x) Phosphate Buffered Saline (PBS), ph 7.0-7.2
  • Application Notes

    Optimal working dilution should be determined by the investigator.

    Comment

    This product is tested and assembled before shipping to ensure that it meets its quality specifications. All kits are tested to confirm that they fall within their defined Inter- and Intra- assay coefficient of variation.

    Sample Volume

    100 μL

    Assay Time

    3 h

    Plate

    Pre-coated

    Protocol

    The microplate provided in this kit has been pre-coated with an antibody specific to Tetraspanin 30 (TSPAN30). Standards or samples are then added to the appropriate microplate wells with a biotin-conjugated antibody specific to Tetraspanin 30 (TSPAN30). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. Then the mixture of substrate A and B is added to generate glow light emission kinetics. Upon plate development, the intensity of the emitted light is proportional to the Tetraspanin 30 (TSPAN30) level in the sample or standard.,

    Assay Precision

    Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Tetraspanin 30 (TSPAN30) were tested 20 times on one plate, respectively
    Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Tetraspanin 30 (TSPAN30) were tested on 3 different plates, 8 replicates in each plate. CV(%) = SD/meanX100
    Intra-Assay: CV<10%
    Inter-Assay: CV<12%

    Restrictions

    For Research Use only
  • Handling Advice

    Do not allow to contact skin or eyes. Calibrators, controls and specimen samples should be assayed in duplicate. Once the procedure has been started, all steps should be completed without interruption.

    Storage

    4 °C,-20 °C

    Storage Comment

    -20°C. Bring all reagents to room temperature before beginning test. The kit may be stored at 4°C for immediate use within two days upon arrival. Reseal any unused strips with desiccant pack. Minimize freeze/thaw cycles.

    Expiry Date

    12 months
  • Target See all CD63 CLIA Kits

    CD63

    Alternative Name

    Tetraspanin 30Cluster of Differentiation 63

    Background

    Gene Aliases: TSPAN30, LAMP-3, ME491, MLA1, OMA81H, Melanoma 1 antigen, Granulophysin, Lysosomal-associated membrane protein 3, Ocular melanoma-associated antigen

    Gene ID

    967

    UniProt

    P08962