MICA ELISA Kit
Quick Overview for MICA ELISA Kit (ABIN6719703)
Target
See all MICA ELISA KitsReactivity
Detection Method
Method Type
Detection Range
Application
Sample Type
-
-
Minimum Detection Limit
- 62.5 pg/mL
-
Supplier Product No.
- koa0483
-
Supplier
- Rockland
-
Purpose
- Human MICA Sandwich ELISA Kit for Quantitative Detection
-
Brand
- AccuSignal™
-
Analytical Method
- Quantitative
-
Specificity
-
Expression system for standard: NS0
Immunogen sequence: E24-W307 -
Cross-Reactivity (Details)
- There is no detectable cross-reactivity with other relevant proteins.
-
Sensitivity
- < 10 pg/mL
-
Components
-
- Antibody-coated 96-well plate
- Target Protein Standard
- Detection antibody
- Detection reagent
- Diluent buffers
- Wash buffers
- Substrate Solution
- Stop solutions
- Adhesive covers
-
Material not included
- Microplate Reader capable of reading absorbance at 450nm. Incubator. Automated plate washer (optional). Pipettes and pipette tips capable of precisely dispensing 0.5 μL through 1 mL volumes of aqueous solutions. Multichannel pipettes are recommended for large amount of samples. Deionized or distilled water. 500 mL graduated cylinders. Test tubes for dilution.
-
-
-
-
Comment
-
Capture antibody and Detection antibody: monoclonal antibody from mouse, polyclonal antibody from goat
-
Sample Volume
- 100 μL
-
Plate
- Pre-coated
-
Protocol
- Useful in Sandwich ELISA for Quantitative Detection of Antigen. Aliquot 0.1 mL per well of the 4000pg/mL, 2000pg/mL, 1000pg/mL, 500pg/mL, 250pg/mL, 125pg/mL, 62.5pg/mL human MICA standard solutions into the precoated 96-well plate. Add 0.1 mL of the sample diluent buffer into the control well (Zero well). Add 0.1 mL of each properly diluted sample of human cell culture supernates, cell lysates, tissue lysates or serum to each empty well. It is recommended that each human MICA standard solution and each sample be measured in duplicate.
-
Assay Precision
-
Intra-Assay Precision (CV%): 7.4%, 7.2%, 7.2%
Inter-Assay Precision (CV%): 8.5%, 8.2%, 7.7% -
Restrictions
- For Research Use only
-
-
-
Storage
- 4 °C,-20 °C
-
Storage Comment
- Store vials at 4°C prior to opening. Centrifuge product if not completely clear after standing at room temperature. This product is stable for 6 months at 4°C as an undiluted liquid. Dilute only prior to immediate use. For extended storage freeze at -20°C or below for 12 months. Avoid cycles of freezing and thawing.
-
Expiry Date
- 12 months
-
-
- MICA (MHC Class I Polypeptide-Related Sequence A (MICA))
-
Alternative Name
- MICA
-
Background
-
Background: MHC class I polypeptide-related sequence A is a protein that in humans is encoded by the MICA gene.1 The MICA gene encodes a 383-amino acid polypeptide with a predicted mass of 43 kD.The MICA and MICB genes occur in a 200-kb region spanning the TNFA and TNFB cluster at 6p21.3.2 MICA and the closely related MICB were recognized by intestinal epithelial T cells expressing diverse V-delta-1 gamma/delta TCRs.3 The MICA protein product is expressed on the cell surface, although unlike canonical class I molecules does not seem to associate with beta-2-microglobulin. It is further distinguished by its unusual exon-intron organization and preferential expression in fibroblasts and epithelial cells. It is thought that MICA functions as a stress-induced antigen that is broadly recognized by NK cells, NKT cells, and most of the subtypes of T cells. MICA and other members of this family may have been selected for specialized functions that are either ancient or derived from those of typical MHC class I genes, in analogy to some of the nonclassic mouse H-2 genes.
Gene Full Name: MHC class I polypeptide-related sequence A
-
Gene ID
- 100507436
-
NCBI Accession
- NP_000238
-
UniProt
- Q29983
-
Pathways
- Activation of Innate immune Response, Transition Metal Ion Homeostasis, Human Leukocyte Antigen (HLA) in Adaptive Immune Response
Target See all MICA ELISA Kits
-