LYVE1 ELISA Kit
Quick Overview for LYVE1 ELISA Kit (ABIN6719878)
Target
See all LYVE1 ELISA KitsReactivity
Detection Method
Method Type
Detection Range
Application
Sample Type
-
-
Minimum Detection Limit
- 31.2 pg/mL
-
Supplier Product No.
- koa0597
-
Supplier
- Rockland
-
Purpose
- Human LYVE-1 Sandwich ELISA Kit for Quantitative Detection
-
Brand
- AccuSignal™
-
Analytical Method
- Quantitative
-
Specificity
-
Expression system for standard: NS0
Immunogen sequence: S24-T238 -
Cross-Reactivity (Details)
- There is no detectable cross-reactivity with other relevant proteins.
-
Sensitivity
- < 10 pg/mL
-
Components
-
- Antibody-coated 96-well plate
- Target Protein Standard
- Detection antibody
- Detection reagent
- Diluent buffers
- Wash buffers
- Substrate Solution
- Stop solutions
- Adhesive covers
-
Material not included
- Microplate Reader capable of reading absorbance at 450nm. Incubator. Automated plate washer (optional). Pipettes and pipette tips capable of precisely dispensing 0.5 μL through 1 mL volumes of aqueous solutions. Multichannel pipettes are recommended for large amount of samples. Deionized or distilled water. 500 mL graduated cylinders. Test tubes for dilution.
-
-
-
-
Comment
-
Capture antibody and Detection antibody: monoclonal antibody from mouse, polyclonal antibody from goat
-
Sample Volume
- 100 μL
-
Plate
- Pre-coated
-
Protocol
- Useful in Sandwich ELISA for Quantitative Detection of Antigen. Aliquot 0.1 mL per well of the 2000pg/mL, 1000pg/mL, 500pg/mL, 250pg/mL, 125pg/mL, 62.5pg/mL, 31.2pg/mL human LYVE-1 standard solutions into the precoated 96-well plate. Add 0.1 mL of the sample diluent buffer into the control well (Zero well). Add 0.1 mL of each properly diluted sample of human cell culture supernates, cell lysates or tissue homogenates to each empty well. It is recommended that each human LYVE-1 standard solution and each sample be measured in duplicate.
-
Assay Precision
-
Intra-Assay Precision (CV%): 6.7%, 6.7%, 5.3%
Inter-Assay Precision (CV%): 7.5%, 6.9%, 7.1% -
Restrictions
- For Research Use only
-
-
-
Storage
- 4 °C,-20 °C
-
Storage Comment
- Store vials at 4°C prior to opening. Centrifuge product if not completely clear after standing at room temperature. This product is stable for 6 months at 4°C as an undiluted liquid. Dilute only prior to immediate use. For extended storage freeze at -20°C or below for 12 months. Avoid cycles of freezing and thawing.
-
Expiry Date
- 12 months
-
-
- LYVE1 (Lymphatic Vessel Endothelial Hyaluronan Receptor 1 (LYVE1))
-
Alternative Name
- LYVE-1
-
Background
-
Background: Extracellular link domain containing 1, also known as LYVE-1 or XLKD1 is a human gene. The International Radiation Hybrid Mapping Consortium mapped the LYVE1 gene to chromosome 11p15.4. This gene encodes a type I integral membrane glycoprotein. The encoded protein acts as a receptor and binds to both soluble and immobilized hyaluronan. This protein may function in lymphatic hyaluronan transport and have a role in tumor metastasis. This gene may play a role in autocrine regulation of cell growth mediated by growth regulators containing cell surface retention sequence binding (CRS). It may act as a hyaluronan (HA) transporter, either mediating its uptake for catabolism within lymphatic endothelial cells themselves, or its transport into the lumen of afferent lymphatic vessels for subsequent re-uptake and degradation in lymph nodes.
Gene Full Name: lymphatic vessel endothelial hyaluronan receptor 1
-
Gene ID
- 10894
-
NCBI Accession
- NP_006682
-
UniProt
- Q9Y5Y7
-
Pathways
- Glycosaminoglycan Metabolic Process
Target See all LYVE1 ELISA Kits
-