Phone:
+1 877 302 8632
Fax:
+1 888 205 9894 (Toll-free)
E-Mail:
orders@antibodies-online.com

Myeloperoxidase ELISA Kit

Human Myeloperoxidase ELISA Kit, Colorimetric assay for quantification of Human Myeloperoxidase.
Catalog No. ABIN8070140
$1,005.40
Plus shipping costs $50.00
96 tests
Shipping to: United States
Delivery in 21 to 42 Business Days

Quick Overview for Myeloperoxidase ELISA Kit (ABIN8070140)

Target

See all Myeloperoxidase (MPO) ELISA Kits
Myeloperoxidase (MPO)

Binding Specificity

Oxidized Form, total

Reactivity

  • 57
  • 23
  • 20
  • 9
  • 9
  • 4
  • 4
  • 3
  • 2
  • 2
  • 2
  • 1
Human

Detection Method

Colorimetric

Method Type

Sandwich ELISA

Application

ELISA

Sample Type

Cell Lysate, Tissue Lysate
  • Purpose

    Measures oxidated Myeloperoxidase and total Myeloperoxidase in human cell and tissue lysates, enabling precise assessment of Myeloperoxidase oxidation by ELISA. This assay can be developed for other species (mouse, rat, etc.) upon request. Contact techsupport@raybiotech.com.

    Analytical Method

    Quantitative

    Components

      Size / Qty
        • Microplate Coated With Anti-Pan-Myeloperoxidase Antibody
        • Positive Control
        • HRP-Conjugated Streptavidin
        • 200 μL
        • Wash Buffer
        • Assay Diluent
        • Lysis Buffer
        • TMB One-Step Substrate Reagent
        • Stop Solution
        • Oxidation Buffer A
        • Oxidation Buffer B
        • Oxidation Labeling Reagent
        • Oxidation Stabilizing Reagent

    Material not included

    • 20 % (v/v) trichloroacetic acid (TCA) solution, ice-cold
    • 1:1 (v/v) ethanol:ethyl acetate
    • Benchtop centrifuge and microcentrifuge (4 °C)
    • Microplate reader capable of measuring absorbance at 450 nm
    • Protease and Phosphatase inhibitors
    • Precision pipettes to deliver 2 μL to 1 mL volumes
    • Adjustable 1-25 mL pipettes for reagent preparation
    • 100 mL and 1 liter graduated cylinders
    • Log-log graph paper or computer and software for ELISA data analysis
    • Absorbent paper
    • Tubes to prepare positive control or sample dilutions
    • Distilled or deionized water
    • Shaker
  • Application Notes

    Optimal working dilution should be determined by the investigator.

    Plate

    Pre-coated

    Protocol

    1. Prepare all reagents, samples and Positive Control as instructed.
    2. Label samples with Oxidation Labeling Reagent
    3. Add Oxidation Stabilizing Reagent to samples.
    4. Precipitate proteins with ice-cold 20 % TCA.
    5. Wash protein pellet twice with 1:1 (v/v) ethanol:ethyl acetate.
    6. Resuspend protein pellets in Oxidation Buffer B.
    7. Add 100 μL sample and Positive Control to each well. Incubate 2.5 hours at room temperature or overnight at 4 °C with gentle shaking.
    8. Add 100 μL prepared HRP-Conjugated Streptavidin solution. Incubate for 1 hour at room temperature with gentle shaking.
    9. Add 100 μL TMB One-Step Substrate Reagent to each well. Incubate 30 minutes at room temperature.
    10. Add 50 μL Stop Solution to each well. Read at 450 nm immediately.

    Restrictions

    For Research Use only
  • Storage

    -20 °C

    Storage Comment

    The entire kit may be stored at -20°C for up to 6 months from the date of shipment. Avoid repeated freeze-thaw cycles.
  • Target See all Myeloperoxidase (MPO) ELISA Kits

    Myeloperoxidase (MPO)

    Alternative Name

    Myeloperoxidase

    Background

    Gene Symbols: MPO

    Background: The Oxidated Myeloperoxidase ELISA Kit uses the "biotin probes" method to biotin label carbonyl groups of oxidized proteins. In this method, the biotin probes first react with carbonyl groups of oxidized proteins to form unstable Schiff bases, which are then further reduced to more stable amines. The biotinylated proteins can then be detected by ELISA. An anti-pan Myeloperoxidase antibody has been coated onto a 96-well plate. Biotinylated samples are pipetted into the wells, and Myeloperoxidase present in a sample is bound to the wells by the immobilized antibody. The wells are washed, and HRP-conjugated streptavidin is used to detect oxidated Myeloperoxidase. The wells are again washed, a TMB substrate solution is added to the wells and color develops in proportion to the amount of oxidated Myeloperoxidase bound. The Stop Solution changes the color from blue to yellow, and the intensity of the color is measured at 450 nm.

    Protein Name (Synonyms): Myeloperoxidase (MPO)

    Gene ID

    4353

    UniProt

    P05164

    Pathways

    Chromatin Binding
You are here:
Chat with us!