Phone:
+1 877 302 8632
Fax:
+1 888 205 9894 (Toll-free)
E-Mail:
orders@antibodies-online.com

IL-2 ELISA Kit

The Rat IL-2 ELISA Kit (ABIN955905) is a Colorimetric ELISA Kit designed to quantify Rat IL-2.
Catalog No. ABIN955905
$1,498.15
Plus shipping costs $50.00
96 tests
Shipping to: United States
Delivery in 11 to 17 Business Days

Quick Overview for IL-2 ELISA Kit (ABIN955905)

Target

See all IL-2 (IL2) ELISA Kits
IL-2 (IL2) (Interleukin 2 (IL2))

Reactivity

  • 22
  • 21
  • 17
  • 7
  • 7
  • 5
  • 5
  • 5
  • 5
  • 3
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
Rat

Detection Method

Colorimetric

Method Type

Sandwich ELISA

Detection Range

31.2-2000 pg/mL

Application

ELISA
  • Minimum Detection Limit

    31.2 pg/mL

    Purpose

    This ELISA kit is a sandwich enzyme immunoassay for the in vitro quantitative measurement of Rat IL2 in serum, plasma, tissue homogenates, cell culture supernates, and other biological fluids.

    Analytical Method

    Quantitative

    Specificity

    This assay has high sensitivity and excellent specificity for detection of Rat IL2. No significant cross- reactivity or interference was observed.

    Sensitivity

    The minimum detectable dose of Rat IL2 is typically less than 8.2 pg/mL.
    The Sensitivity of this assay, or Lower Limit of Detection (LLD) was defined as the lowest protein concentration that could be differentiated from zero. It was determined by the mean O.D. value of 20 replicates of the zero calibrator plus three standard deviations.

    Characteristics

    The microtiter plate provided in this kit has been pre-coated with an antibody specific to IL2. Calibrators and samples are then added to the appropriate microtiter plate wells with a biotin-conjugated polyclonal antibody preparation specific for IL2. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. Then the TMB substrate solution is added to each well. Only those wells that contain IL2, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of a sulfuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450 nm +/- 2 nm. The concentration of IL2 in the samples is then determined by comparing the O.D. of the samples to the calibration curve.

    Components

    Pre-coated, ready to use 96-well plate (1x)
    Calibrator (lyophilized) (2x)
    Calibrator Diluent (1 x 20 mL)
    Detection Reagent A (1 x 120 µL)
    Detection Reagent B (1 x 120 µL)
    Assay Diluent A (2X concentrate) (1 x 6 mL)
    Assay Diluent B (2X concentrate) (1 x 6 mL)
    TMB Substrate (1 x 9 mL)
    Stop Solution (1 x 6 mL)
    Wash Buffer (30X concentrate) (1 x 20 mL)
    Plate sealer for 96 wells (4x).

    Material not included

    1. Microplate reader with 450 +/- 10 nm filter.
    2. Precision single and multi-channel pipettes and disposable tips.
    3. Eppendorf Tubes for diluting samples.
    4. Deionized or distilled water.
    5. Absorbent paper for blotting the microtiter plate.
    6. Container for Wash Solution
  • Comment

    The calibration curve concentrations used for the ELISA's were 2, 000, 1000, 500, 250, 125, 62.5, 31.2 pg/mL.

    Plate

    Pre-coated

    Calculation of Results

    Average the duplicate readings for each calibrator, control, and sample and subtract the average zero calibrator optical density. Create a calibration curve by reducing the data using computer software capable of generating a four parameter logistic (4-PL) curve-fit. As an alternative, construct a calibration curve by plotting the mean absorbance for each calibrator on the x-axis against the concentration on the y-axis and draw a best fit curve through the points on the graph. The data may be linearized by plotting the log of the IL2 concentrations versus the log of the O.D. and the best fit line can be determined by regression analysis. This procedure will produce an adequate but less precise fit of the data. It is recommended to use some related software to do this calculation. If samples have been diluted, the concentration read from the calibration curve must be multiplied by the dilution factor.

    Restrictions

    For Research Use only
  • Storage

    -20 °C

    Storage Comment

    All reagents should be stored according to their label. The Calibrators, Detection Reagent A, Detection Reagent B and the 96-well plate should be stored at -20° C upon receipt. The unused strips should be kept in a sealed bag with the desiccant provided to minimize exposure to damp air. Opened test kits will remain stable until the expiration date, provided they are stored as above.

    Expiry Date

    The expiry date is stated on the label.
  • Target See all IL-2 (IL2) ELISA Kits

    IL-2 (IL2) (Interleukin 2 (IL2))

    Alternative Name

    IL2

    Pathways

    JAK-STAT Signaling, Regulation of Leukocyte Mediated Immunity, Positive Regulation of Immune Effector Process, Production of Molecular Mediator of Immune Response, Activated T Cell Proliferation
You are here:
Chat with us!