Phone:
+1 877 302 8632
Fax:
+1 888 205 9894 (Toll-free)
E-Mail:
orders@antibodies-online.com

IgA Secretory Component (Free & Bound) antibody

There are 2+ publications for this product available. The Goat Polyclonal anti-IgA Secretory Component antibody is suitable to detect IgA Secretory Component in samples from Human. It has been validated for IEP and RID.
Catalog No. ABIN457970
$631.79
Plus shipping costs $50.00
1 mL
Shipping to: United States
Delivery in 1 to 3 Business Days

Quick Overview for IgA Secretory Component (Free & Bound) antibody (ABIN457970)

Target

IgA Secretory Component

Reactivity

  • 17
  • 9
  • 1
  • 1
Human

Host

  • 11
  • 10
  • 3
  • 3
Goat

Clonality

  • 16
  • 11
Polyclonal

Conjugate

  • 11
  • 5
  • 4
  • 3
  • 2
  • 2
Un-conjugated

Application

  • 20
  • 13
  • 7
  • 6
  • 6
  • 5
  • 5
  • 5
  • 4
  • 3
  • 3
  • 1
  • 1
  • 1
Immunoelectrophoresis (IEP), Radial Immunodiffusion (RID)
  • Binding Specificity

    • 10
    • 5
    • 5
    • 1
    Free & Bound

    Purpose

    Goat anti Human secretory component (free and bound)

    Specificity

    Precipitating polyclonal Goat antiSerum to Human secretory component

    Cross-Reactivity (Details)

    Inter-species cross-reactivity is a normal feature of antibodies to Serum proteins, since homologous proteins of different species frequently share antigenic determinants. Cross-reactivity of this antiSerum has not been tested in detail.

    Characteristics

    Tested in immunoelectrophoresis, double radial immunodiffusion and ELISA against a panel of appropriate secretions and purified Ig isotypes. The antiserum reacts with both bound secretory component (secretory IgA) and with the free SC present in human secretions. In immunoelectrophoresis against human milk, using a high electroendosmosis agar plate, free SC is precipitated in the alph-2 region. The antiserum does not react with other molecular forms of IgA, or with any other secretory or plasma protein. In precipitating techniques as immunoelectrophoresis and single and double radial immunodiffusion to identify the presence secretory component in human serum or other body fluids and to determine its concentration.

    Purification

    Delipidated, heat inactivated, lyophilized, stable whole antiserum

    Immunogen

    Secretory component is present in human secretions bound to secretory IgA (sIgA) and in free form. Secretory IgA (sIgA) functions as a dimer or polymer and accounts for almost all specific mucosal antibody activity. A molecule of sIgA is made up of two molecules of IgA, one J chain and one SC (MW 65,000). The dimer IgA is transported into secretions by its binding to the SC on the epithelial cells. Under normal conditions, sIgA contains both subclasses IgA1 and IgA2, since both are capable of binding SC. SC also has an affinity for polymeric IgM. Purified free human secretory component isolated from pooled milk is used for immunization. Freund's complete adjuvant is used in the first step of the immunization procedure.

    Isotype

    IgG
  • Application Notes

    Precipitation assays. In immunoelectrophoresis use 2 μL serum or equivalent against 120 μL antiserum. In double radial immunodiffusion use a rosette arrangement with 10 μL antiserum in 3 mm diameter centre well and 2 μL serum samples (neat and serially diluted) in 2 mm diameter peripheral wells.

    Restrictions

    For Research Use only
  • Format

    Lyophilized

    Reconstitution

    Reconstitute the lyophilized antiserum by adding 1 mL sterile distilled water.

    Buffer

    Delipidated, heat inactivated, lyophilized, stable whole antiserum No preservative added. Total protein and IgG concentrations in the antiserum are comparable to those of pooled normal goat serum. No foreign proteins added.

    Preservative

    Without preservative

    Storage

    4 °C,-20 °C

    Storage Comment

    The lyophilized antiserum is shipped at ambient temperature and may be stored at +4°C, prolonged storage at or below -20°C. Dilutions may be prepared by adding phosphate buffered saline (PBS, pH 7.2). Repeated thawing and freezing should be avoided. If a slight precipitation occurs upon storage, this should be removed by centrifugation. It will not affect the performance of the antiserum. Diluted antiserum should be stored at +4°C, not refrozen, and preferably used the same day.
  • Roos Ljungberg, Joshua, Skogh, Eklund, Sköld, Karimi, Nyrén, Svärd, Catrina, Kastbom: "Secretory anti-citrullinated protein antibodies in serum associate with lung involvement in early rheumatoid arthritis." in: Rheumatology (Oxford, England), Vol. 59, Issue 4, pp. 852-859, (2020) (PubMed).

    Roos, Martinsson, Ziegelasch, Sommarin, Svärd, Skogh, Kastbom: "Circulating secretory IgA antibodies against cyclic citrullinated peptides in early rheumatoid arthritis associate with inflammatory activity and smoking." in: Arthritis research & therapy, Vol. 18, Issue 1, pp. 119, (2017) (PubMed).

  • Target

    IgA Secretory Component

    Alternative Name

    Secretory Immunoglobulin A (SIgA)
You are here:
Chat with us!