Phone:
+1 877 302 8632
Fax:
+1 888 205 9894 (Toll-free)
E-Mail:
orders@antibodies-online.com

MMAF Antibody Drug Conjugate (ADC) ELISA Kit

Reactivity: Chemical Colorimetric Competition ELISA 0.019-2000 μg/mL Serum, Tissue Samples
Catalog No. ABIN2014352
  • Target
    MMAF Antibody Drug Conjugate (ADC)
    Reactivity
    Chemical
    Detection Method
    Colorimetric
    Method Type
    Competition ELISA
    Detection Range
    0.019-2000 μg/mL
    Minimum Detection Limit
    0.019 μg/mL
    Application
    ELISA
    Purpose
    This test kit is intended for use in the quantitative determination of antibody-MMAF-conjugate level in test sample. It is useful for pre-clinical and clinical pharmacology study of MMAF Antibody Drug Conjugate (ADC).
    Samples from tissue/cell culture and serum samples from human, rat, mouse, primate, etc. can be used directly with this kit.- Both humanized monoclonal antibody based MMAF-ADC and mouse monoclonal antibody based MMAF-ADC can be measured with this kit.
    Brand
    EDI™
    Sample Type
    Tissue Samples, Serum
    Analytical Method
    Quantitative
    Cross-Reactivity (Details)
    This MMAF-ADC EIA doesn't show any cross reactivity to MMAE-ADC, DM1-ADC, DUO-3-ADC, and DUO-6-ADC.
    Components
    1. Anti-MMAF Antibody Coated Microplate.One microplate with twelve by eight strips (96 wells total) coated with specific anti-MMAF antibody. The plate is framed and sealed in a foil zipper bag with a desiccant. This reagent should be stored at 2-8 °C and is stable until the expiration date on the kit box.
    2. HRP Conjugated MMAF.One vial containing 3 mL of ready to use HRP labeled MMAF in a stabilized protein matrix. This reagent should be stored at 2-8 °C and is stable until the expiration date on the kit box.
    3. ELISA Wash Concentrate.One bottle containing 3 mL of 30-fold concentrate. Before use the contents must be diluted with 87 mL of demineralized water and mixed well. Upon dilution, this yields a working wash solution containing a surfactant in phosphate buffered saline with a non-azide, non-mercury preservative. The diluted wash solution may be stored at room temperature and is stable until the expiration date on the kit box.
    4. ELISA HRP Substrate.One bottle containing 15 mL of tetramethylbenzidine (TMB) with hydrogen peroxide. This reagent should be stored at 2-8 °C and is stable until the expiration date on the kit box.
    5. ELISA Stop Solution.One bottle containing 15 mL of stop solution. This reagent may be stored at 2-8 °C or room temperature and is stable until the expiration date on the kit box.
    6. Antibody-MMAF Conjugated Zero Calibrator.One vial containing 30mL zero calibrator (30721) . This reagent is used for diluting the calibration stock t make assay calibrators, as well as for diluting test samples. This reagent should be stored at 2-8 °C and is stable until the expiration date on the kit box.
    7. Antibody-MMAF Conjugated Calibration Stock. Not provided in the kit (optional) One vial (3072
    2. containing the calibration stock of antibody-MMAF-conjugate in a lyophilized (0.5 mL) serum based matrix with a non-azide preservative. Refer to the vial for exact concentration of the standard. This reagent should be stored at 2-8 °C and is stable until the expiration date on the kit box.
    Material not included
    1. Antibody-MMAF Conjugated Stock
    2. Precision single channel pipettes capable of delivering 2 μL, 50 μL, 100 μL, etc
    3. Disposable pipette tips suitable for above volume dispensing
    4. Aluminum foil
    5. Deionized or distilled water
    6. Plastic microtiter well cover or polyethylene film
    7. ELISA multichannel wash bottle or automatic (semi-automatic) washing system
    8. Spectrophotometric microplate reader capable of reading absorbance at 450/650 or 450/2. nm.
  • Assay Time
    4 h
    Plate
    Pre-coated
    Protocol
    This EIA kit is designed, developed and produced for the quantitative measurement of antibody MMAF conjugate in serum. The assay utilizes the competitive immunoassay technique with an antibody that exclusively binds to MMAF.Assay calibrators (antibody MMAF conjugate) and test serum samples are added directly to wells of a microtiter plate that is coated with specific anti-MMAF antibody. Subsequently, a horseradish peroxidase (HRP) conjugated MMAF is added to each well. During the incubation period, the antibody MMAF conjugate competes with the HRP conjugated MMAF for the limited binding sites of anti-MMAF antibody. An immune complex of well coated anti-MMAF antibody HRP conjugated MMAF is formed. The unbound antibodies and buffer matrix are removed in the subsequent washing step. For the detection of this immunocomplex, the well is then incubated with a substrate solution in a timed reaction, which is terminated with an acidic reagent (i.e. ELISA stop solution). The absorbance is then measured in a spectrophotometric microplate reader. The enzymatic activity of the immunocomplex bound to the wall of each microtiter well is inversely proportional to the amount of antibody-MMAF conjugate in the test sample. A calibration curve is generated by plotting the absorbance versus the respective antibody-MMAF conjugate concentration for each calibrator on a 4-parameter or log-logit curve fitting. The concentration of antibody-MMAF conjugate in test samples is determined directly from this calibration curve.
    Reagent Preparation

    (1) Prior to use allow all reagents to come to room temperature. Reagents from different kit lot numbers should not be combined or interchanged.
    (2) ELISA Wash Concentrate must be diluted to working solution prior to use. Please see REAGENTS section for details.
    (3) Using EDI Calibrators:Reconstitute calibration stock with 0.5 mL DI-water. Dilute the reconstituted calibration stock Place a sufficient number of Anti-MMAF antibody coated microwell strips in a holder to determine calibrators and unknown samples in duplicates.

    Assay Procedure

    (1) Add 100 μL of calibrators and test samples into the designated microwells.
    (2) Seal the plate wells securely, cover with foil or other material to protect from light, and rotate on an ELISA plate shaker (small orbit radius) for 30 minutes at 400 to 450 rpm.
    (3) Immediately add 25 μL of HRP Conjugated MMAF to each well. (Note: no wash step before add the HRP conjugated MMAF)
    (4) Seal the plate wells securely, cover with foil or other material to protect from light, and rotate on an ELISA plate shaker (small orbit radius) for 2 hr. 10 minutes at 400 to 450 rpm.
    (5) Wash each well 5 times by dispensing 350 μL of working wash solution into each well and then completely aspirating the contents. Alternatively, an automated microplate washer can be used.
    (6) Add 100 μL of ELISA HRP Substrate into each of the wells.
    (7) Cover the plate with aluminum foil or other material to avoid exposure to light. Incubate plate static, at room temperature for 20 minutes.
    (8) Immediately add 100 μL of ELISA Stop Solution into each of the wells. Mix gently.
    (9) Read the absorbance at 450 nm.

    Calculation of Results

    It is recommended to use a 4-parameter or log-logit calibration curve fitting.
    1. Calculate the average absorbance for each pair of duplicate test results
    2. The calibration curve is generated by the corrected absorbance of all calibrator levels on the ordinate against the calibrator concentration. Appropriate computer assisted data reduction programs should be used for the calculation of results.The antibody-MMAF conjugate concentrations for the test samples are read directly from the calibration curve using their respective corrected absorbance.

    Assay Precision
    The intra-assay precision was validated by measuring three calibrators (L3, L4 and L7) in six replicate determinations. The CV% is 5.5%, 4.9% and 6.1%.
    Restrictions
    For Research Use only
  • Precaution of Use
    The reagents must be used in professional laboratory. Source material for reagents containing bovine serum was derived in the contiguous 48 United States. It was obtained only from healthy donor animals maintained under veterinary supervision and found free of contagious diseases. Wear gloves while performing this assay and handle these reagents as if they are potentially infectious. Avoid contact with reagents containing TMB, hydrogen peroxide, or sulfuric acid. TMB may cause irritation to skin and mucous membranes and cause an allergic skin reaction. TMB is a suspected carcinogen. Sulfuric acid may cause severe irritation on contact with skin. Do not get in eyes, on skin, or on clothing. Do not ingest or inhale fumes. On contact, flush with copious amounts of water for at least 15 minutes. Use Good Laboratory Practices.
    Storage
    4 °C