Phone:
+1 877 302 8632
Fax:
+1 888 205 9894 (Toll-free)
E-Mail:
orders@antibodies-online.com

BAD ELISA Kit

This Colorimetric ELISA kit is designed for the quantitative measurement of Human BAD.
Catalog No. ABIN5526723

Quick Overview for BAD ELISA Kit (ABIN5526723)

Target

See all BAD ELISA Kits
BAD (BCL2-Associated Agonist of Cell Death (BAD))

Binding Specificity

pSer112, total

Reactivity

  • 9
  • 7
  • 7
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
Human

Detection Method

Colorimetric

Method Type

Cell ELISA

Application

ELISA

Sample Type

Adherent Cell Culture
  • Purpose

    Human and Mouse Phospho-MARCKS (Ser152/156) and Total MARCKS Cell-Based ELISA Cell-Based ELISA Kit. This assay semi-quantitatively measures BAD phosphorylated at Serine-112 as well as total BAD in adherent cell lines.

    Analytical Method

    Semi-Quantitative

    Specificity

    This ELISA kit recognizes Human BAD phosphorylated at site Serine-112 as well as total BAD.

    Characteristics

    • Rapidly measure phosphorylated protein in adherent cell lines
    • Simultaneously measure Phosphorylated protein and pan protein in one experiment (for normalization purpose)
    • No sample lysis is needed
    • Compatible with a standard ELISA plate reader

    Components

    • Uncoated 96-well Strip Microplate
    • Wash Buffers
    • Fixing Solution
    • Quenching Buffer
    • Blocking Buffer
    • Anti-phospho antibody
    • Anti-pan antibody
    • HRP-Conjugated Secondary Antibody
    • TMB One-Step Substrate
    • Stop Solution

    Material not included

    • Distilled or deionized water
    • 100 mL and 1 liter graduated cylinders
    • Tubes to prepare sample dilutions
    • Protease and Phosphatase inhibitors
    • Precision pipettes to deliver 2 μL to 1 mL volumes
    • Adjustable 1-25 mL pipettes for reagent preparation
    • Benchtop rocker or shaker
    • Microplate reader capable of measuring absorbance at 450 nm
  • Application Notes

    Optimal working dilution should be determined by the investigator.

    Plate

    Pre-coated

    Protocol

    1. Prepare all reagents and samples as instructed in the manual.
    2. Add 100 μL of sample or positive control to each well.
    3. Incubate 2.5 h at RT or O/N at 4 °C.
    4. Add 100 μL of prepared primary antibody to each well.
    5. Incubate 1 h at RT.
    6. Add 100 μL of prepared 1X HRP-Streptavidin to each well.
    7. Incubate 1 h at RT.
    8. Add 100 μL of TMB One-Step Substrate Reagent to each well.
    9. Incubate 30 min at RT.
    10. Add 50 μL of Stop Solution to each well.
    11. Read at 450 nm immediately.

    Restrictions

    For Research Use only
  • Storage

    -20 °C

    Storage Comment

    Upon receipt, the kit should be stored at -20 °C. Please use within 6 months from the date of shipment. After initial use, Wash Buffer Concentrate (Item B), Assay Diluent (Item E), TMB One-Step Substrate Reagent (Item H), HRP-Streptavidin (Item G), Stop Solution (Item I) and Cell Lysate Buffer (Item J) should be stored at 4 °C to avoid repeated freeze-thaw cycles. Return unused wells to the pouch containing desiccant pack, reseal along entire edge and store at -20 °C. Reconstituted Positive Control (Item K) should be stored at -70 °C.

    Expiry Date

    6 months
  • Target See all BAD ELISA Kits

    BAD (BCL2-Associated Agonist of Cell Death (BAD))

    Alternative Name

    BAD

    Gene ID

    572

    UniProt

    Q92934

    Pathways

    MAPK Signaling, PI3K-Akt Signaling, RTK Signaling, Apoptosis, Fc-epsilon Receptor Signaling Pathway, Positive Regulation of Peptide Hormone Secretion, Carbohydrate Homeostasis, Positive Regulation of Endopeptidase Activity, Regulation of Carbohydrate Metabolic Process, Hepatitis C, CXCR4-mediated Signaling Events
You are here:
Chat with us!