Phone:
+1 877 302 8632
Fax:
+1 888 205 9894 (Toll-free)
E-Mail:
orders@antibodies-online.com

PAX6 ELISA Kit

PAX6 Reactivity: Mouse Colorimetric Sandwich ELISA 46.88 pg/mL - 3000 pg/mL Plasma, Serum, Tissue Homogenate
Catalog No. ABIN6975711
  • Target See all PAX6 ELISA Kits
    PAX6 (Paired Box 6 (PAX6))
    Reactivity
    • 1
    • 1
    Mouse
    Detection Method
    Colorimetric
    Method Type
    Sandwich ELISA
    Detection Range
    46.88 pg/mL - 3000 pg/mL
    Minimum Detection Limit
    46.88 pg/mL
    Application
    ELISA
    Purpose
    For the quantitative determination of mouse paired box 6 (PAX6) concentrations in serum, plasma, tissue homogenates.
    Sample Type
    Plasma, Serum, Tissue Homogenate
    Analytical Method
    Quantitative
    Specificity
    This assay has high sensitivity and excellent specificity for detection of mouse PAX6. No significant cross-reactivity or interference between mouse PAX6 and analogues was observed. Note: Limited by current skills and knowledge, it is impossible for us to complete the cross-reactivity detection between mouse PAX6 and all the analogues, therefore, cross reaction may still exist.
    Sensitivity
    11.72 pg/mL
    Components
    • Assay plate
    • Standard
    • HRP-avidin (100 x concentrate)
    • Biotin-antibody (100 x concentrate)
    • Sample Diluent
    • HRP-avidin Diluent
    • Biotin-antibody Diluent
    • Wash Buffer (25 x concentrate)
    • TMB Substrate
    • Stop Solution
    • Adhesive Strip
    Top Product
    Discover our top product PAX6 ELISA Kit
  • Application Notes
    Optimal working dilution should be determined by the investigator.
    Sample Volume
    100 μL
    Assay Time
    1 - 4.5 h
    Plate
    Pre-coated
    Protocol
    1. Prepare reagents, samples and standards as instructed.
    2. Add 100 µL standard or sample to each well. Incubate 2 hours at 37 °C.
    3. Remove the liquid of each well, don't wash.
    4. Add 100 µL Biotin-antibody (1x) to each well. Incubate 1 hour at 37 °C.
    5. Aspirate and wash 3 times.
    6. Add 100 µL HRP-avidin (1x) to each well. Incubate 1 hour at 37 °C
    7. Aspirate and wash 5 times.
    8. Add 90 μL of TMB Substrate to each well. Incubate for 15-30 minutes at 37 °C. Protect from light.
    9. Add 50 µL Stop Solution to each well. Read at 450 nm within 5 minutes.
    Reagent Preparation
    1. Biotin-antibody (1x) - Centrifuge the vial before opening. Biotin-antibody requires a 100-fold dilution. A suggested 100-fold dilution is 10 μL of Biotin-antibody + 990 μL of Biotin-antibody Diluent.
    2. HRP-avidin (1x) - Centrifuge the vial before opening. HRP-avidin requires a 100-fold dilution. A suggested 100-fold dilution is 10 μL of HRP-avidin + 990 μL of HRP-avidin Diluent.
    3. Wash Buffer (1x) - If crystals have formed in the concentrate, warm up to room temperature and mix gently until the crystals have completely dissolved. Dilute 20 mL of Wash Buffer Concentrate (25 x) into deionized or distilled water to prepare 500 mL of Wash Buffer (1 x).
    4. Standard Centrifuge the standard vial at 6000-10000rpm for 30s. Reconstitute the Standard with 1.0 mL of Sample Diluent. Do not substitute other diluents. This reconstitution produces a stock solution of 3000 pg/mL. Mix the standard to ensure complete reconstitution and allow the standard to sit for a minimum of 15 minutes with gentle agitation prior to making dilutions. Pipette 250 μL of Sample Diluent into each tube (S0-S6). Use the stock solution to produce a 2-fold dilution series (below). Mix each tube thoroughly before the next transfer. The undiluted Standard serves as the high standard (3000 pg/mL). Sample Diluent serves as the zero standard (0 pg/mL).
    Note:
    • Kindly use graduated containers to prepare the reagent. Please don't prepare the reagent directly in the Diluent vials provided in the kit.
    • Bring all reagents to room temperature (18-25 °C) before use for 30 min.
    • Prepare fresh standard for each assay. Use within 4 hours and discard after use.
    • Making serial dilution in the wells directly is not permitted.
    • Please carefully reconstitute Standards according to the instruction, and avoid foaming and mix gently until the crystals have completely dissolved. To minimize imprecision caused by pipetting, use small volumes and ensure that pipettors are calibrated. It is recommended to suck more than 10 μL for once pipetting.
    • Distilled water is recommended to be used to make the preparation for reagents. Contaminated water or container for reagent preparation will influence the detection result.
    Sample Preparation
    • It is recommended to use fresh samples without long storage, otherwise protein degradation and denaturationmay occur in these samples, leading to false results. Samples should therefore be stored for a short periodat 2 - 8 °C or aliquoted at -20 °C (≤1 month) or -80 °C (≤ 3 months). Repeated freeze-thawcycles should be avoided. Prior to assay, the frozen samples should be slowly thawed and centrifuged toremove precipitates.
    • If the sample type is not specified in the instructions, a preliminary test is necessary to determinecompatibility with the kit.
    • If a lysis buffer is used to prepare tissue homogenates or cell culture supernatant, there is a possibilityof causing a deviation due to the introduced chemical substance.The recommended dilution factor is for reference only.
    • Please estimate the concentration of the samples before performing the test. If the values are not in therange of the standard curve, the optimal sample dilution for the particular experiment has to be determined.Samples should then be diluted with PBS (pH =7.0-7.2).
    Assay Precision
    Intra-assay Precision (Precision within an assay): CV%<8% Three samples of known concentration were tested twenty times on one plate to assess.
    Inter-assay Precision (Precision between assays): CV%<10% Three samples of known concentration were tested in twenty assays to assess.
    Restrictions
    For Research Use only
  • Storage
    4 °C,-20 °C
    Storage Comment
    Unopened kit Store at 2 - 8°C. Do not use the kit beyond the expiration date. May be stored for up to 1 month at 2 - 8°C. Coated assay Try to keep it in a sealed aluminum foil bag, plate and avoid the damp. Standard May be stored for up to 1 month at 2 - 8° C. If Biotin-antibody don't make recent use, better keep it store at HRP-avidin -20°C. Biotin-antibody Diluent Opened kit HRP-avidin Diluent Sample May be stored for up to 1 month at 2 - 8°C. Diluent Wash Buffer TMB Substrate Stop Solution *Provided this is within the expiration date of the kit.
    Expiry Date
    6 months
  • Target See all PAX6 ELISA Kits
    PAX6 (Paired Box 6 (PAX6))
    Alternative Name
    paired box 6 (PAX6 Products)
    Synonyms
    pax6 ELISA Kit, an2 ELISA Kit, mgda ELISA Kit, wagr ELISA Kit, pax-6 ELISA Kit, pax6a ELISA Kit, xpax6 ELISA Kit, XLPAX6 ELISA Kit, MGC52531 ELISA Kit, PAX-6 ELISA Kit, AN ELISA Kit, AN2 ELISA Kit, D11S812E ELISA Kit, MGDA ELISA Kit, WAGR ELISA Kit, Pax-6 ELISA Kit, pax6b ELISA Kit, 1500038E17Rik ELISA Kit, AEY11 ELISA Kit, Dey ELISA Kit, Gsfaey11 ELISA Kit, Sey ELISA Kit, PAXZF-A ELISA Kit, Pax6.1 ELISA Kit, cb280 ELISA Kit, fc20e07 ELISA Kit, pax-a ELISA Kit, pax[zf-a] ELISA Kit, paxzfa ELISA Kit, wu:fc20e07 ELISA Kit, zfpax-6a ELISA Kit, zfpax-6b ELISA Kit, paired box 6 ELISA Kit, paired box 6 L homeolog ELISA Kit, paired box 6 S homeolog ELISA Kit, paired box 6a ELISA Kit, PAX6 ELISA Kit, pax6 ELISA Kit, Pax6 ELISA Kit, pax6.L ELISA Kit, pax6.S ELISA Kit, pax6a ELISA Kit
    Background

    Abbreviation: PAX6

    Alias: AN, AN2, D11S812E, MGC17209, MGDA, WAGR, OTTHUMP00000038834, THUMP00000038836, THUMP00000038837, THUMP00000038838, TTHUMP00000038839, THUMP00000038840, aired box gene 6

    UniProt
    P63015
    Pathways
    Peptide Hormone Metabolism, Carbohydrate Homeostasis
You are here:
Support