Phone:
+1 877 302 8632
Fax:
+1 888 205 9894 (Toll-free)
E-Mail:
orders@antibodies-online.com

C3 ELISA Kit

C3 Reactivity: Pig Colorimetric Sandwich ELISA 62.5-4000 ng/mL
Catalog No. ABIN955825
  • Target See all C3 ELISA Kits
    C3 (Complement Component 3 (C3))
    Reactivity
    • 6
    • 6
    • 6
    • 5
    • 4
    • 4
    • 4
    • 3
    • 3
    • 3
    • 2
    • 1
    • 1
    Pig
    Detection Method
    Colorimetric
    Method Type
    Sandwich ELISA
    Detection Range
    62.5-4000 ng/mL
    Minimum Detection Limit
    62.5 ng/mL
    Application
    ELISA
    Purpose
    The kit is a sandwich enzyme immunoassay for the in vitro quantitative measurement of pig C3 in serum, plasma and other biological fluids.
    Analytical Method
    Quantitative
    Specificity
    This assay has high sensitivity and excellent specificity for detection of pig C3. No significant cross- reactivity or interference between pig C3 and analogues was observed. Note: Limited by current skills and knowledge, it is impossible for us - complete the cross-reactivity detection between pig C3 and all the other analogues, therefore, cross reaction may still exist.
    Sensitivity
    The minimum detectable dose of pig C3 is typically less than 15.8 ng/mL.
    The Sensitivity of this assay, or Lower Limit of Detection (LLD) was defined as the lowest protein concentration that could be differentiated from zero. It was determined the mean O.D. Value of 20 replicates of the zero calibrator plus three standard deviations.
    Characteristics
    The microtiter plate provided in this kit has been pre-coated with an antibody specific to C3. Calibrators or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated polyclonal antibody preparation specific for C3. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. Then a TMB substrate solution is added to each well. Only those wells that contain C3, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of a sulfuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450 nm +/- 10 nm. The concentration of C3 in the samples is then determined by comparing the O.D. of the samples to the calibration curve.
    Components
    Pre-coated, ready to use 96-well strip plate (1x)
    Calibrator (lyophilized) (2x)
    Calibrator Diluent (1 x 20 mL)
    Detection Reagent A (1 x 120 µL)
    Detection Reagent B (1 x 120 µL)
    Assay Diluent A (2X concentrate) (1 x 6 mL)
    Assay Diluent B (2X concentrate) (1 x 6 mL)
    TMB Substrate (1 x 9 mL)
    Stop Solution (1 x 6 mL)
    Wash Buffer (30X concentrate) (1 x 20 mL)
    Plate sealer for 96 wells (4x).
    Material not included
    1. Microplate reader with 450 +/- 10 nm filter.
    2. Precision single and multi-channel pipettes and disposable tips.
    3. Eppendorf Tubes for diluting samples.
    4. De-ionized or distilled water.
    5. Absorbent paper for blotting the microtiter plate.
    6. Container for Wash Solution.
    Featured
    Discover our best selling C3 ELISA Kit
    Top Product
    Discover our top product C3 ELISA Kit
  • Comment

    The calibration curve concentrations used for the ELISA's were 4, 000 ng/mL, 2, 1000 ng/mL, 500 ng/mL, 250 ng/mL, 125 ng/mL, 62.5 ng/mL.

    Plate
    Pre-coated
    Calculation of Results

    Average the duplicate readings for each calibrator, control, and samples and subtract the average zero calibrator optical density. Create a calibration curve on log-log graph paper, with C3 concentration on the y-axis and absorbance on the x-axis. Draw the best fit straight line through the calibrator points and it can be determined by regression analysis. Using some plot software is also recommended. If samples have been diluted, the concentration read from the calibration curve must be multiplied by the dilution factor.

    Restrictions
    For Research Use only
  • Storage
    -20 °C
    Storage Comment
    All the reagents should be kept according to the labels on vials. The Calibrator, Detection Reagent A, Detection Reagent B and the 96-well strip plate should be stored at -20° C upon being received. The unused strips should be kept in a sealed bag with the desiccant provided to minimize exposure to damp air. Opened test kits will remain stable until the expiration date shown, provided it is stored as prescribed above.
    Expiry Date
    The expiry date is stated on the label.
  • Target See all C3 ELISA Kits
    C3 (Complement Component 3 (C3))
    Alternative Name
    Complement C3 (C3 Products)
    Synonyms
    AHUS5 ELISA Kit, ARMD9 ELISA Kit, ASP ELISA Kit, C3a ELISA Kit, C3b ELISA Kit, CPAMD1 ELISA Kit, AI255234 ELISA Kit, HSE-MSF ELISA Kit, Plp ELISA Kit, C3 ELISA Kit, C3-1 ELISA Kit, sb:cb26 ELISA Kit, si:dkey-76b14.4 ELISA Kit, wu:fi34b03 ELISA Kit, wu:fj86e11 ELISA Kit, C3d ELISA Kit, asp ELISA Kit, cpamd1 ELISA Kit, c3 ELISA Kit, complement C3 ELISA Kit, complement component 3 ELISA Kit, complement component c3a, duplicate 1 ELISA Kit, complement component 3 L homeolog ELISA Kit, complement component C3 ELISA Kit, complement C3-like ELISA Kit, C3 ELISA Kit, c3a.1 ELISA Kit, c3.L ELISA Kit, LOC443475 ELISA Kit, c3 ELISA Kit, c3-1 ELISA Kit, LOC100060539 ELISA Kit
    Pathways
    Complement System, Regulation of Leukocyte Mediated Immunity, Positive Regulation of Immune Effector Process, Regulation of G-Protein Coupled Receptor Protein Signaling
You are here: