Phone:
+1 877 302 8632
Fax:
+1 888 205 9894 (Toll-free)
E-Mail:
orders@antibodies-online.com

Insulin ELISA Kit

This Colorimetric ELISA kit is designed for the quantitative measurement of Human, Dog and Rabbit Insulin.
Catalog No. ABIN956117
$1,280.77
Plus shipping costs $50.00
96 tests
Shipping to: United States
Delivery in 11 to 17 Business Days

Quick Overview for Insulin ELISA Kit (ABIN956117)

Target

See all Insulin (INS) ELISA Kits
Insulin (INS)

Reactivity

  • 26
  • 16
  • 16
  • 11
  • 9
  • 6
  • 5
  • 4
  • 4
  • 3
  • 2
  • 2
  • 2
  • 1
  • 1
Human, Dog, Rabbit

Detection Method

Colorimetric

Method Type

Sandwich ELISA

Application

ELISA
  • Purpose

    The Dog, Human and Rabbit Insulin ELISA is for the quantitative determination of insulin in dog, human and rabbit serum.

    Analytical Method

    Quantitative

    Characteristics

    This kit is a stable and convenient assay system for measurement of insulin (human, rabbit and dog) in serum samples. The processing of proinsulin, which occurs within the B cell, yields insulin and C-peptide. Insulin and C-peptide are secreted in equimolar quantities into blood circulation. Therefore, the measurement of insulin in blood is very important, and also provides valuable information to evaluate the pancreatic B cell function. This kit for the determination of insulin concentration (IR-insulin) in serum samples of human, rabbit and dog is based on a sandwich enzyme immunoassay by using a combination of guinea pig anti-human insulin antibody (coated on plate), recombinant insulin calibrator, biotinylated guinea pig anti-human insulin antibody and HRP-labeled streptoavidin (SA-HRP). Finally, HRP enzyme activity is determined by o-Phenylenediamine dihydrochloride (OPD) and the concentration of insulin is calculated. The kit is characterized by sensitive quantification, high specificity and no influences with other components in samples and needlessness of sample pretreatment. Human insulin calibrator is a recombinant product.This ELISA kit for determination of insulin (IR-insulin) in serum is based on a sandwich enzyme immunoassay. The 96- well plate is coated with guinea pig anti-human insulin antibody and insulin calibrator or samples are added to the wells for their immunoreaction. After incubation and plate washing, biotinylated guinea pig anti-human insulin antibody is introduced to the wells and the antibody - antigen - labeled antibody complex is formed on the surface of the well. After rinsing out excessive labeled antibody, HRP-labeled streptoavidin (SA-HRP) is added to bind to labeled antibody. Finally, HRP enzyme activity is determined by o-Phenylenediamine dihydrochloride (OPD) and the concentration of insulin is calculated.

    Components

    1. Antibody-Coated Plate MTP: 1 plate (96-well) Guinea pig anti-human insulin antibody
    2. Calibrator Lyophilized: 1 vial (100 ng) Recombinant human insulin
    3. Labeled Antibody Liquid: 1 bottle (12 mL) Biotinylated guinea pig anti-human insulin Ab
    4. Substrate Buffer Liquid: 1 bottle (24 mL) 0.015% Hydrogen peroxide
    5. OPD Tablet: 2 tablets o-Phenylenediamine dihydrochloride
    6. Stop Solution Liquid: 1 bottle (12 mL) 1M H2SO4
    7. Buffer Solution Liquid: 1 bottle (20 mL) Phosphate buffer
    8. SA-HRP Solution Liquid: 1 bottle (12 mL) HRP-labeled streptoavidin
    9. Wash Solution Liquid: 1 bottle (50 mL) Concentrated saline Concentrate
    10. Plate Seal: 3 sheets

    Material not included

    Photometer for microtiter plate (plate reader), which can read absorbance up to 2.5 at 492 nm
    Rotator for microtiter plate
    Washing device for microtiter plate and dispenser with aspiration system
    Micropipettes, multi-channel pipettes for 8 wells or 12 wells and their tips
    Test tubes for preparation of Calibrator Solution
    Graduated cylinder (1,000 mL)
    Distilled water or de-ionized water
  • Plate

    Pre-coated

    Reagent Preparation

    1. Preparation of Calibrator: Reconstitute the insulin calibrator (lyophilized, 100 ng/vial) with 1 mL of buffer solution, which affords a 100 ng/mL calibrator solution. Then, 0.2 mL of the calibrator solution is diluted with 0.4 mL of buffer solution to yield a 33.33 ng/mL calibrator solution. Repeat the dilution to make each calibrator solution of 11.11, 3.70, 1.23, 0.41 and 0.137 ng/mL. Buffer solution is used as 0 ng/mL. Note: Calibrator Solution must be prepared immediately before assay. Use clean test tubes or vessels.
      2. Preparation of Substrate Solution: Dissolve one OPD Tablet in 11 mL of Substrate Buffer. Note: Substrate Solution must be prepared immediately before assay. Use clean test tubes or vessels.
      3. Preparation of Wash Solution: Dilute 50 mL of Wash Solution Concentrate to 1,000 mL with distilled or de-ionized water. Diluted Wash Solution is stable for 6 months at 4°C. Note: During storage of the Wash Solution Concentrate at 4°C, precipitates may be observed, however, they will dissolve when diluted. Diluted washing solution is stable for 6 months at 4°C.
      4. Other reagents are ready for use.

    Sample Preparation

    Samples must be used as soon as possible after collection. If the samples are to be tested at a later time, they should be divided into test tubes in small amounts and frozen at or below -30°C. Avoid repeated freeze/thaw cycles.

    Assay Procedure

    1. Warm the reagents and samples to room temperature (20-30°C) before beginning the test.
      2. Add 0.35 mL/well of washing solution into the wells and aspirate the washing solution in the wells. Repeat this washing procedure further thrice (total four times).
      3. Fill 150 µL of buffer solution into wells first and then introduce 25 µL of calibrator solutions (0, 0.137, 0.41, 1.23, 3.70, 11.11, 33.33 and 100 ng/mL) or samples into wells.
      4. Cover the plate with a Plate Seal and incubate it at 4°C overnight for 16~20 hours. (Still, plate shaker not needed)
      5. After 4°C incubation, move the plate to room temperature and wait for half hour, take off the Plate Seal, aspirate and wash the wells four times with approximately 0.35 mL/well of washing solution.
      6. Pipette 100 µL of labeled antibody into the wells.
      7. Cover the plate with a Plate Seal and incubate it for two hours at room temperature. During the incubation, the plate should be shaken with a microtiter plate shaker. During continuous shaking of test plate, the plate shaker may be heated up. It is recommended to place styrene foam or plywood between the plate and the shaker. During incubation except color reaction, the test plate should be shaking gently by plate shaker to promote immunoreaction.
      8. Take off the Plate Seal, aspirate the solution in the wells and wash the wells four times with approximately 0.35 mL/well of washing solution.
      9. Pipette 100 µL of SA-HRP solution into the wells.
      10. Cover the plate with a Plate Seal and incubate it at room temperature (20-30°C) for one hour. During the incubation, the plate should be shaken with a plate shaker.
      11. Resolve OPD tablet with 11 mL of substrate buffer. It should be prepared immediately before use.
      12. Take off the Plate Seal, aspirate the solution in the wells and wash the wells four times with approximately 0.35 mL/well of washing solution.
      13. Pipette 100 µL of substrate solution into the wells, cover the plate with a Plate Seal and incubate it for 30 minutes at room temperature.
      14. Add 100 µL of stop solution into the wells to stop color reaction.
      15. Read the optical absorbance of the wells at 492 nm. Read optical absorbance of reaction solution in wells as soon as possible after stopping the color reaction. Note: Perform all determinations in duplicate.

    Calculation of Results

    Calculate mean absorbance values of wells containing the Calibrators and plot a calibration curve on logarithmic graph paper (abscissa: concentration of Calibrators, ordinate: absorbance values of Calibrators). Use the calibration curve to read insulin concentrations in samples from the corresponding absorbance values. When a sample value exceeds 100 ng/mL, it needs to be diluted with buffer solution until the value is within the assay range.

    Restrictions

    For Research Use only
  • Storage

    4 °C
  • Target See all Insulin (INS) ELISA Kits

    Insulin (INS)

    Alternative Name

    Insulin

    Pathways

    NF-kappaB Signaling, RTK Signaling, Positive Regulation of Peptide Hormone Secretion, Peptide Hormone Metabolism, Hormone Activity, Carbohydrate Homeostasis, ER-Nucleus Signaling, Regulation of Carbohydrate Metabolic Process, Feeding Behaviour, Autophagy, Negative Regulation of intrinsic apoptotic Signaling, Brown Fat Cell Differentiation, Positive Regulation of fat Cell Differentiation