Phone:
+1 877 302 8632
Fax:
+1 888 205 9894 (Toll-free)
E-Mail:
orders@antibodies-online.com

CCL2 ELISA Kit

CCL2 Reactivity: Mouse Colorimetric Sandwich ELISA 15.6-1000 pg/mL
Catalog No. ABIN1112743
  • Target See all CCL2 ELISA Kits
    CCL2 (Chemokine (C-C Motif) Ligand 2 (CCL2))
    Reactivity
    • 13
    • 9
    • 7
    • 4
    • 3
    • 3
    • 2
    • 2
    • 2
    • 2
    • 2
    • 2
    • 1
    • 1
    Mouse
    Detection Method
    Colorimetric
    Method Type
    Sandwich ELISA
    Detection Range
    15.6-1000 pg/mL
    Minimum Detection Limit
    15.6 pg/mL
    Application
    ELISA
    Analytical Method
    Quantitative
    Sensitivity
    < 6 pg/mL
    Components
    1. One 96-well plate pre-coated with anti-Mouse MCP-1 antibody 2. Lyophilized Mouse MCP-1 standards: 2 tubes (10ng / tube) 3. Sample / Standard diluent buffer: 30ml 4. Biotin conjugated anti-Mouse MCP-1 antibody (Concentrated): 130 µl.
    Material not included
    1. 37 °C incubator 2. Microplate reader (wavelength: 450nm) 3. Precise pipette and disposable pipette tips 4. Automated plate washer 5. ELISA shaker 6. 1.5ml of Eppendorf tubes 7. Plate cover 8. Absorbent filter papers 9. Plastic or glass container with volume of above 1L
    Featured
    Discover our best selling CCL2 ELISA Kit
    Top Product
    Discover our top product CCL2 ELISA Kit
  • Comment

    This kit was based on sandwich enzyme-linked immune-sorbent assay technology. Anti-MCP-1 polyclonal antibody was pre-coated onto 96-well plates. And the biotin conjugated anti-MCP-1 polyclonal antibody was used as detection antibodies. The standards test samples and biotin conjugated detection antibody were added - the wells subsequently and wash with wash buffer. Avidin-Biotin-Peroxidase Complex was added and unbound conjugates were washed away with wash buffer. TMB substrates were used - visualize HRP enzymatic reaction. TMB was catalyzed by HRP - produce a blue color product that changed into yellow after adding acidic stop solution. The density of yellow is proportional - the MCP-1 amount of sample captured in plate. Read the O.D. absorbance at 450 nm in a microplate reader and then the concentration of MCP-1 can be calculated.

    Plate
    Pre-coated
    Reagent Preparation
    1. Before the experiment, centrifuge each kit component for several minutes to bring down all reagents to the bottom of tubes. 2. It is recommend to measure each standard and sample in duplicate. 3. Do NOT let the plate completely dry at any time! Since the dry condition can inactivate the biological material on the plate. 4. Do not reuse pipette tips and tubes to avoid cross contamination. 5. Do not use the expired components and the components from different batches. 6. To avoid the marginal effect of plate incubation for temperature differences (the marginal wells always get stronger reaction), it is recommend to equilibrate the ABC working solution and TMB substrate for at least 30 min at room temperature (37°C ) before adding to wells.The TMB substrate (Kit Component 8) is colorless and transparent before use, if not, please contact us for replacement.
    Sample Preparation

    Preparation of sample and reagents 1. Sample Isolate the test samples soon after collecting, then, analyze immediately (within 2 hours). Or aliquot and store at -20 °C for long term. Avoid multiple freeze-thaw cycles.
    Tissue lysate, body fluids and cell culture supernatants: Centrifuge to remove precipitate, analyze immediately or aliquot and store at -20 °C .
    Serum: Coagulate the serum at room temperature (about 4 hours). Centrifuge at approximately 2000 × g for 20 min. Analyze the serum immediately or aliquot and store at -20 °C .
    Plasma: Collect plasma with EDTA as the anticoagulant. Centrifuge for 20 min at 2000 x g within 30 min of collection. Analyze immediately or aliquot and store frozen at -20 °C. Heparin and citrate can not be used as anticoagulant. Note: 1. Coagulate blood samples completely, then, centrifuge, and avoid hemolysis and particle. 2. NaN3 can not be used as test sample preservative, since it is the inhibitor for HRP.

    Restrictions
    For Research Use only
  • Preservative
    Sodium azide, Thimerosal (Merthiolate)
  • Target See all CCL2 ELISA Kits
    CCL2 (Chemokine (C-C Motif) Ligand 2 (CCL2))
    Alternative Name
    MCP-1 / CCL2 (CCL2 Products)
    Synonyms
    GDCF-2 ELISA Kit, HC11 ELISA Kit, HSMCR30 ELISA Kit, MCAF ELISA Kit, MCP-1 ELISA Kit, MCP1 ELISA Kit, SCYA2 ELISA Kit, SMC-CF ELISA Kit, AI323594 ELISA Kit, JE ELISA Kit, Scya2 ELISA Kit, Sigje ELISA Kit, MCP-1A ELISA Kit, MCP1A ELISA Kit, C-C motif chemokine ligand 2 ELISA Kit, chemokine (C-C motif) ligand 2 ELISA Kit, C-C motif chemokine 2 ELISA Kit, CCL2 ELISA Kit, Ccl2 ELISA Kit, LOC101120093 ELISA Kit
    Background
    Monocyte chemotactic protein-1(MCP-1), known as chemmkine(C-C motif) ligand 2(CCL2) or small inducible cytokine A2, is a small cytokine belonging to the CC chemokine family. The CCL2 gene is located on chromosome 17 (17q11.2-q21.1) in humans, and spans 1,927 bases. It has three exons and two introns, and produced as a protein precursor containing signal peptide of 23 amino acids and a mature peptide of 76 amino acids. The predicted weight is 11.025 kiloDaltons (kDa). MCP-1 has been implicated in the pathogenesis of diseases characterized by monocytic infiltrates, like psoriasis, rheumatoid arthritis and atherosclerosis. It induces amylin expression through ERK1/ ERK2/ JNK-AP1 and NF-țB related signaling pathways independent of CCR2. Amylin upregulation by CCL2 may contribute to elevation of plasma amylin in obesity and insulin resistance.
    Pathways
    Cellular Response to Molecule of Bacterial Origin, Positive Regulation of Immune Effector Process, ER-Nucleus Signaling, Unfolded Protein Response, The Global Phosphorylation Landscape of SARS-CoV-2 Infection
You are here:
Support